Instruction Manual
18
18. ALARMS
LIGHTS ALARM SOLUTION
on
General alarm Machine needs service. Contact Customer
Services
+ ashing
The drip tray (A13) is missing or has not
been inserted correctly
Extract the drip tray then put back cor-
rectly in the appliance
on
Descaling must be performed Descale the appliance as described in sec-
tion "14. Descaling"
ashing quickly
The dial (B8) is in the descaling position Turn the dial to one of the beverage
positions
+ ashing
The portalter has been detached before
grinding has ended or pressing has been
performed too quickly
Repeat grinding
The coee grinder coee guide is clogged Clean as described in section "13.10
Cleaning the "Smart tamping station""
and section "19. Troubleshooting" in cor-
respondence to g. 50.
The burrs are blocked by foreign matter Remove the foreign matter and clean the
burrs as described in section "13.8 Clean-
ing the burrs".
+ ashing
The machine
is being turned on for the
rst time and the water circuit must be
lled.
Proceed as described in section "3. Set-
ting up the appliance"
If the water softener lter (C6) is present,
an air bubble may have been released in-
side the circuit, obstructing delivery
Remove water softner lter and press the
button (B6) corresponding to the
light (g. 9). Delivery begins and stops
automatically. Reinsert water softner as
described in section "11. Activating the
water softener lter".
The grinding is too ne and the coee is
delivered too slowly or not at all
Extract the portalter and repeat the
operations to make the coee, bearing
in mind the indications in section "4.4
Adjusting the quantity of ground coee
in the lter" and table "16. How to make
perfect coee".
The tank has been inserted incorrectly and
the valves on the bottom are not open
Press the tank down lightly to open the
valves on the bottom
Scale in the water circuit Descale as described in section "14.
Descaling"
…
→