Split Air Conditioner Thank you for choosing DE'LONGHI air conditioner. For correct opertion, please read this owner’s manual carefully before operating the unit and keep it carefully for consultation.
CONTENTS Operation and maintenance ■ Notices for operation ..................................1 ■ Notices for use ......................................3 ■ Names and functions of each part ......................... 4 ■Operation of wireless remote control ........................5 ■Emergency operation ................................10 ■Clean and care ....................................12 ■ Troubleshooting ....................................15 Installation service ■ Notices for installation ...............
Operation and maintenance-notices for operation ★ Earth: The ground be connected! ★ Be sure to pull out the power ★ Select the most appropriate templug when not using the air co- perature. nditioner for a long time. Keep room cooler than outside about 5 degree. If not, please ask the qualified personnel to install. Furthermore, don't connect each wire to the gas pipe, water pipe, drainage pipe or any other improper places.
Notices for operation ★ If the supply cord is damaged, it must be replaced ★ The airflow direction can be adjusted appro- priately. At operating, adjust the vertical airflow direction by adjusting the louvers of upward/downward direction. And then, hold two ends of left and right louver to adjust the horizontal airflow. by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
Notices for use Working principle and special functions for cooling Principle: Air conditioner absorbs heat in the room and transmit to outdoor and discharged, so that indoorambient temperature decreased, its cooling capacity will increase or decrease by outdoor ambient temperature.
Names and functions of each part Indoor unit Air in ⑵ ⑶ ⑷ The pattern in displayer: ⑸ Air out :Cool ⑹ ⑴ :Dry :Fan Wireless remote control :Heat :Run ⑴ Remote control ⑵ Front panel :Set temp.
遥控器各按键的名称及作用 Operation of wireless remote control Names and functions of wireless remote control Note: Be sure that there are no obstructions between receiver and remote controoler; Don't drop or throw the remote control; Don't let any liquid in the remote control and put the remote control directly under the sunlight or any place where is very hot. SLEEP button Signal transmitter ● Press this button, Sleep On and Sleep Off can be selected. After powered on, Sleep Off is defaulted.
Operation of wireless remote control Names and functions of wireless remote control This wireless remote control is universal, and it could be used for many units, some buttons of this control which are not available to this unit will not be described below. I FEEL button ● Press this button once, to turn on the I FEEL function, then the figure of I FEEL icon will appear. After this function started, the remote control will send temperature to the main unit in every 10 minutes.
Operation of wireless remote control Names and functions of wireless remote control This wireless remote control is universal, and it could be used for many units, some buttons of this control which are not available to this unit will not be described below. TIMER ON BUTTON ● Remote control Timer On setting: "ON" flashes and will conceal,numeral segment become timer-on setting status.Pressing or could adjust the numeral segment of time,increase or decrease 1minute per time within 5 seconds.
Operation of wireless remote control Guide for operation- General operation 1. After powered on, press ON/OFF button, the unit will start to run.(Note: When it is powered on, the guide louver of main unit will close automatically.) 2. Press MODE button, select desired running mode, or press COOL or HEAT mode to enter into the corresponding operation directly. 3. Pressing +or - button, to set the desired temperature. 4. Press key to set the fan speed.
Operation of wireless remote control ★ About lock Press and buttons simultaneously to lock or unlock the keyboard. If the remote controller is locked, press any button, the remote control can't work, you must unlock the keyboard. ★ About swing 1. Press swing button continuously more than 2seconds,the main unit will swing back and forth from up to down, and then loosen the button, the unit will stop swinging and present position of guide louver will be kept immediately. 2.
Emergency operation (only on some models) Displayer indicator light control of indoor unit It's a special selective buttonfor the users ,who are not accustomed to the light at sleeping. ● Get the displayer indicator light on: When setting the light function,the mark will display on the remote controller screen by pressing this button. In which case,the dissplayer indicator light will be on if the AC receives this signal.
Emergency Operation (only on some models) Emergency Operation When the wireless remote control is lost or damaged, please use the manual switch, at this time, it is running in Auto Run mode that will not change the temperature setting value and fan speed. The manual switch can be operated as follow: ● ● At operation: When the unit stopped running, press ON/OFF button, unit will enter into AUTO RUN mode.
Clean and care Caution ● ● ● Turn power off and pull out the power plug before cleaning air conditioner, or it may cause electric shock. Never sprinkle water on the indoor unit and the outdoor unit for cleaning because it can cause an electric shock. Volatile liquid (e.g. thinner or gasoline) will damage the air conditioner. (So wipe the units with a dry soft cloth, or a cloth slightly moistened with water or cleanser.
Clean and care Check before use ① Be sure that nothing obstructs the air outlet and intake vents. ② Check that whether ground wire is properly connected or not. ③ Check that whether the batteries of air conditioner are changed or not. ④ Check that whether the installation stand of the outdoor unit is damaged or not. If damaged, please contact the dealer. Maintain after use ① Turn main power off. ② Clean the filter and indoor and outdoor units' bodies.
Troubleshooting CAUTION Don't attempt to repair the air conditioner by yourself, it can cause an electric shock or fire. Please check the following items before asking for repair, it can save your time and money. Phenomenon Troubleshooting Not operate immediately when the air conditioner is restarted. Once the air conditioner is stopped, it will not operate in approximately 3minutes to protect itself. ● Waiting There's unusual smell blowing from the outlet after operation is started.
Troubleshooting Phenomenon Troubleshooting ● Has the power been shut down? The unit can not run. ● Is power plug loosed? ● Is the circuit protection device tripped off or not? ● Is voltage higher or lower? (Tested by professionals) Breaking off Cooling(Heating) efficiency is not good. ● Is the TIMER correctly used? ● Is Temp.
Troubleshooting Phenomenon Indoor unit cannot deliver air. Troubleshooting ● In HEAT mode, when the temperature of indoor heat exchanger is very low, that will stop deliver air in order to prevent cool air. (Within 2min) ● In HEAT mode, when the outdoor temperature is low or high humidity, there are much frost be formed on the outdoor heat exchanger, that the unit will automatically defrost, indoor unit stop blowing air for 3-12min. During the defrosting, there is water flowing out or vapor be produced.
Notices for installation Important Notices 1.The unit installation work must be done by qualified personnel according to the local rules and this manual. 2.Before installating, please contact with local authorized maintenance center, if unit is not installed by the authorized maintenance center, the malfunction may not solved, due to discommodious contacts. 3.When removing the unit to the other place, please firstly contact with the authorized Maintenance Center in the local area. 4.
Notices for installation Outdoor Unit Installation Position Selection 1.Select a location from which noise and outflow air emitted by unit will not inconvenience neighbors, animals, plants. 2.Select a location where there should be sufficient ventilation. 3.Select a location where there should be no obstructions cover the inlet and outlet vent. 4.The location should be able to withstand the full weight and vibration of the outdoor unit and permit safe installation. 5.
Installation dimension diagram Installation dimension diagram Space to the ceiling Above Space to the wall Above Above Space to the wall Above Air outlet side Space to the floor The dimensions of the space necessary for correct installation of the appliance including the minimum permissible distances to adjacent structures Space to the obstruction Above ● Above Air inlet side e ov Ab Above Space to the wall Space to the wall Above ve o Ab Air outlet side 19
Install indoor unit Install the rear panel 1.Always mount the rear panel horizontally. Due to the water tray of indoor unit has been adopted the both-way drainage design, the outlet of water tray should be adjusted slightly down when installing, that is taking the outlet of the water tray as the center of a circle, the included angle between the evaporator and level should be 0 or more, that is good for condensing water drainage. Wall 2.Fix the rear panel on the wall with screws.
Install indoor unit NOTE: When connecting the electric wire if the wire length is not enough, please contact with the authorized service shop to buy a exclusive electric wire that is long enough and the joint on the wire are not allowed. The electric wiring must be correctly connected, wrong connection may cause spare parts malfunction. ● Tighten the terminal screw in order to prevent loose. ● After tighten the screw, slight pull the wire and confirm whether is it firm or not.
Install outdoor unit Electric wiring 1. Disassemble the handle on the outdoor unit right side plate. 2.Take off cord anchorage. Connect and fix power connect Handle cord (for cooling and heating unit,connect and fix power connect cord and signal control wire)to terminal block. 3.Fix the power connection cable with cord anchorage, (for cooling and heating unit, use the cord anchorage to fix the power connection cable and the signal control wire).
Check after installation and test operation Check after installation Items to be checked Possible malfunction Has it been fixed firmly? The unit may drop, shake or emit noise. Have you done the refrigerant leakage test? It may cause insufficient cooling(heating) capacity Is heat insulation sufficient? It may cause condensation and dripping. Is water drainage well? It may cause condensation and dripping.
Installation and Maintenance of Healthy Filter Installation Instructions 1. Forcibly pull the panel for a specific angle from the two ends of the front panel according to the arrow direction. Then pull the air filter downwards to remove it. (See Fig.a) Fig. a 2. Mount the healthy filter onto the air filter,(as shown in Fig.b). If the air filter cannot be installed, please mount the healthy filter on the front case. (as shown in Fig.c) Fig. b Air filter Healthy filter Healthy filter Fig. c 3.
TECHNICAL DATA On - Off GENERAL INFORMATION MODELS (****) General data Electricity supply 9K 10 1,0 24K 28K V~Hz R410 A (**) 16 20 1,5 2,5 10 1,0 20 2,5 A mm mm L 845 845 940 1178 1178 H 275 275 298 326 326 mm P 180 180 200 253 mm 253 A 150 mm B 150 mm mm C 2500 D 150 mm E 300 mm L 848 848 913 980 mm P 320 320 378 427 427 mm H 980 540 592 680 790 790 mm C 300 mm D 500 mm F 300 mm E 2000 mm Indoor unit net weight Outdoor unit net
TECHNICAL DATA - INVERTER - GENERAL INFORMATION I MODELS (****) General data Electricity supply 9K 10 1,0 28K V~Hz R410A(**) 20 20 2,5 2,5 10 1,0 20 2,5 A mm L 790 845 940 1008 1178 265 275 298 315 326 mm P 170 180 200 219 253 mm mm A 150 mm B 150 mm mm C 2500 D 150 mm E 300 mm L 776 848 955 955 980 P 320 320 424 424 427 mm H 540 540 700 700 790 mm mm C 300 mm D 500 mm F 300 mm E 2000 mm 10 32 Liquid Gas Liquid Gas 11 36 35 20
5717310161/06.