Instruction Manual

9
COMFORTEMP BUTTON
With the “COMFORTEMP” button and both switches pressed,
the appliance is automatically set to reach and maintain what
is considered to be the comfort temperature.
A green light comes on to indicate activation of “COMFOR-
TEMP”. In this mode the temperature is automatically set only
by the “COMFORTEMP. To deactivate this mode and return to
thermostat operation, press the COMFORTEMP button again.
MAINTENANCE
Before carrying out any operation on the radiator, unplug
from the electric mains and wait for it to cool.
The oil-lled electric radiator requires no particular mainte-
nance. It is sucient to remove the dust with a soft, dry cloth.
Never use abrasive powders or solvents. If necessary remove
concentrations of dirt using a vacuum cleaner.
TECHNICAL CHARACTERISTICS
Supply voltage See rating label
Absorbed power
TROUBLESHOOTING
PROBLEM CAUSE SOLUTION
The appliance doesn't work Be sure it is plugged in and that the elec-
trical outlet is working.
Check for any obstruction.
The temperature may be set too low.
Plug into the power outlet.
Remove the obstruction and let the appliance
cool down. If the appliance doesn't work please
contact Customer Experience.
Set the temperature to a higher position.
ELECTRICAL CONNECTION (UK ONLY)
A) If your appliance comes tted with a plug, it will incorporate a 13 Amp fuse. If it does not t your socket, the plug should be
cut o from the mains lead, and an appropriate plug tted, as below. WARNING: Very carefully dispose of the cut o plug
after removing the fuse: do not insert in a 13 Amp socket elsewhere in the house as this could cause a shock hazard.
With alternative plugs not incorporating a fuse, the circuit must be protected by a 15 Amp fuse. If the plug is a moulded-
on type, the fuse cover must be re-tted when changing the fuse using a 13 Amp Asta approved fuse to BS 1362. In the
event of losing the fuse cover, the plug must NOT be used until a replacement fuse cover can be obtained from your nearest
electrical dealer. The colour of the correct replacement fuse cover is that as marked on the base of the plug.
B) If your appliance is not tted with a plug, please follow the instructions provided below:
WARNING - THIS APPLIANCE MUST BE EARTHED
IMPORTANT
The wires in the mains lead are coloured in accordance with the following code:
Green and yellow: Earth
Blue: Neutral
Brown: Live
As the colours of the wires in the mains lead may not correspond with the coloured markings identifying the terminals in your
plug, proceed as follows:
The green and yellow wire must be connected to the terminal in the plug marked with the letter E or the earth symbol or
coloured green or green and yellow. The blue wire must be connected to the terminal marked with the letter N or coloured black.
The brown wire must be connected to the terminal marked with the letter L or coloured red.