Product Manual

Copyright 2007, Delmhorst Instrument Co.
Page 15 of 30
4. After you have scrolled through all five room pages, select DONE if satisfied with your
selections. This will take you back to the CREATE JOB sub menu.
5. Press DONE to save the job. This will bring you back to the main menu.
TO TAKE SCAN READINGS IN ENHANCED MODE
TO SET THE ALARM IN ENHANCED SCAN MODE:
1. If you wish to set the alarm to beep after a pre-selected relative value is reached,
highlight option #1: SCAN MODE from the ENHANCED main menu. If you have already
set up a job, this will bring you to the SCAN screen. If you have not set up a job, the meter
will prompt you to create one and then will return to the MAIN MENU, at which point you may
select #1: SCAN MODE.
2. Use the and keys and highlight ALARM: OFF. Press the SELECT key to enter the
alarm sub menu.
3. The default status of the alarm is “OFF.” Press the SELECT key to turn it on.
4. After the alarm is turned on, use the keys to scroll up or down to a higher or lower
alarm value.
5. After you have selected the alarm value, use the key to highlight DONE. Press SELECT
to get back to the SCAN screen.
NOTE: Default alarm setting for SCAN mode is 300.
TO TAKE A SCAN READING:
1. In the MAIN Menu, highlight option #1: SCAN MODE
If you have already set up a job, this will bring you to the SCAN screen. If you have not
set up a job, the meter will prompt you to create one and then will return to the MAIN
MENU, at which point you may select #1: SCAN MODE.
This screen contains the following information: Job # and ID, current location (LOC),
number of records (REC) for the current room, and memory used (MEM).
Rooms are ordered as in APPENDIX A, Floor (F), Wall (W), and then Ceiling (C). Only
locations for which a material was chosen can be selected for measurements.