Owners Manual

Icon Description Condition Corrective action
(for example, a temperature
out of range or fan failure).
A cooling fan is removed or has
failed.
System cover, cooling shroud, EMI
filler panel, memory-module
blank, or back-filler bracket is
removed.
Ambient temperature is too high.
External airflow is obstructed.
SeeGetting help.
Memory indicator Blinks amber if a memory
error occurs.
See the system event log or system
messages for the location of the failed
memory. Reinstall the memory
device. If the issue persists, seeGetting
help.
PCIe indicator Blinks amber if a PCIe card
experiences an error.
Restart the system. Update any
required drivers for the PCIe card.
Reinstall the card. If the issue persists,
seeGetting help.
NOTE: For more information
about supported PCIe cards,
seeExpansion card installation
guidelines.
Hard drive indicator codes
Figure 2. Hard drive indicators
1. Hard drive activity indicator 2. Hard drive status indicator
11