Setup Guide
Power
Heat dissipation
NOTE: Heat dissipation is calculated using
the power supply wattage rating.
2891 BTU/hr maximum (750 W)
4100 BTU/hr maximum (1100 W)
Voltage
NOTE: This system is also designed to be
connected to IT power systems with a
phase to phase voltage not exceeding 230
V.
100–240 V AC, autoranging, 50/60 Hz
Battery
Coin-cell battery 3 V CR2032 Lithium coin cell
Physical
Height 87.3 mm (3.44 inch)
Width
With rack latches 482.4 mm (18.98 inch)
Without rack latches 444 mm (17.48 inch)
Depth (includes bezel) 755.8 mm (29.75 inch)
Weight (maximum)
3.5-inch hard disk drive systems 32.5 kg (71.5 lbs)
Weight (empty)
3.5-inch hard disk drive systems 10.3 kg (22.7 lbs)
Environmental
NOTE: For additional information about environmental measurements for specific system
configurations, see dell.com/environmental_datasheets.
Temperature
Operating
Continuous operation: 10 °C to 35 °C at 10% to 80%
relative humidity (RH), with 26 °C max dew point.
De-rate maximum allowable dry bulb temperature
at 1 °C/300 m above 900 m (1 °F per 550 ft).
NOTE: For information abput supported
expanded operating temperature range and
configurations, see support.dell.com.
Storage –40 °C to 65 °C (–40 °F to 149 °F) with a maximum
temperature gradation of 20 °C per hour.
Relative Humidity
7