Owners Manual
Table Of Contents
- Dell XC6320 Web-Scaled Hyperconverged Appliance Owner's Manual
- About the Dell XC6320
- About your system
- Accessing system features during startup
- Front panel features and indicators
- Hard drive indicator patterns
- Back panel features and indicators
- System-board assembly configurations
- LAN indicator codes
- Power and system board indicator codes
- Power Supply Unit indicator codes
- iDRAC heart beat LED
- Documentation references
- Performing initial system configuration
- Pre-operating system management applications
- Navigation keys
- System Setup
- Entering System Setup
- System Setup details
- System BIOS Settings details
- System Information details
- Memory Settings details
- Processor Settings details
- SATA Settings details
- Boot Settings details
- Network Settings screen details
- Integrated Devices details
- Serial Communication details
- System Profile Settings details
- System Security Settings details
- Miscellaneous Settings details
- System setup options at boot
- About Boot Manager
- Changing the boot order
- Choosing the system boot mode
- Assigning a system and setup password
- Deleting or changing system and setup password
- Installing and removing system components
- Safety instructions
- Recommended tools
- Opening and closing the system
- Inside the system
- Cooling fans
- Hard drives
- SATADOM
- Power supply units
- System board assembly
- Air baffle
- Heat sinks
- Processors
- Expansion card assembly and expansion card
- Riser card
- LSI 2008 Mezzanine Card
- Mezzanine card bridge board
- System memory
- System battery
- System board
- Troubleshooting your system
- Safety first—for you and your system
- Minimum configuration to POST
- Safety first – for you and your system
- Installation-related issues
- Troubleshooting system startup failure
- Troubleshooting external connections
- Troubleshooting the video subsystem
- Troubleshooting a USB device
- Troubleshooting a serial I/O device
- Troubleshooting a NIC
- Troubleshooting a wet system
- Troubleshooting a damaged system
- Troubleshooting the system battery
- Troubleshooting PSUs
- Troubleshooting system cooling issues
- Troubleshooting a fan
- Troubleshooting system memory
- Troubleshooting a hard drive
- Troubleshooting a storage controller
- Troubleshooting expansion cards
- Troubleshooting processors
- IRQ assignment conflicts
- Jumpers and connectors
- Getting help
Installing the cooling shroud
CAUTION: Many repairs may only be done by a certified service technician. You should only
perform troubleshooting and simple repairs as authorized in your product documentation, or as
directed by the online or telephone service and support team. Damage due to servicing that is
not authorized by Dell is not covered by your warranty. Read and follow the safety instructions
that are shipped with your product.
Follow the safety guidelines listed in the Safety instructions section.
Replace the cooling shroud into the system board assembly. Make sure that the four latches are
properly engaged with the heat sink bases and the latches click in place.
NOTE: When installing the cooling shroud, make sure the arrow of the mark on the cooling
shroud points to processor 1, and keep the flat surface of the cooling shroud horizontal.
Figure 21. Top view of the installed cooling shroud
1. Install the system board assembly.
2. Reconnect the peripherals and connect the system to the electrical outlet.
3. Turn on the system, including any attached peripherals.
Related Links
Installing the system board assembly
Heat sinks
The heat sink transfers heat away form the processor as the processor is unable to dissipate sufficient
heat to moderate this temperature. The heat sink is designed to maximize its surface area in contact with
the cooling medium surrounding it, such as the air. Thermal grease improve the heat sink's performance
by filling air gaps between the heat sink and the heat spreader on the processor.