Owners Manual
Figure 23. Installing a hard drive into a hard drive carrier
1 screw (4) 2 hard drive
3 hard drive carrier
Next steps
Install the hot swappable hard drive carrier.
Related links
Installing a hot swappable hard drive carrier
Cooling fans
Your system supports:
• Up to four cooling fans in a non-redundant power supply unit (PSU) conguration.
• Up to ve cooling fans in a redundant PSU conguration.
NOTE
: Fan 1 must be installed in a redundant PSU
conguration.
NOTE: Hot-swap removal or installation of the fans is not supported.
NOTE: Each fan is listed in the systems management software, referenced by the respective fan number. If there is a problem
with a particular fan, you can easily identify and replace the proper fan by noting the fan numbers on the cooling fan assembly.
Removing a cooling fan
Prerequisites
NOTE
: The procedure for removing each fan is identical.
1 Follow the safety guidelines listed in the Safety instructions section.
2 Follow the procedure listed in the Before working inside your system section.
3 Remove the cooling shroud.
4 If required, remove the cooling shroud.
Steps
1 Disconnect the power cable from the power connector on the system board or power interposer board.
2 Lift the fan out of the cooling fan bracket.
Installing and removing system components
41