Owners Manual
Indicator codes for redundant power supply unit
Each AC power supply unit (PSU) has an illuminated translucent handle that indicates whether power is present or whether a power fault
has occurred.
Figure 8. AC PSU status indicator
1
AC PSU status indicator or handle
Table 9. Redundant AC PSU status indicator
Convention Power Indicator
Pattern
Condition
A Green A valid power source is connected to the PSU and the PSU is operational.
B Flashing green When the PSU rmware is being updated, the PSU handle ashes green.
CAUTION: Do not disconnect the power cord or unplug the PSU when updating
rmware. If rmware update is interrupted, the PSUs will not function. You must
roll back the PSU rmware by using Dell Lifecycle Controller. For more
information, see Dell Lifecycle Controller User’s Guide at Dell.com/idracmanuals.
C Flashing green and
turns o
When hot-adding a PSU, the PSU handle ashes green ve times at 4 Hz rate and turns
o. This indicates that there is a PSU mismatch with respect to eciency, feature set,
health status, and supported voltage.
CAUTION: For AC PSUs, use only PSUs with the Extended Power Performance
(EPP) label on the back.
NOTE: Ensure that both the PSUs are of the same capacity.
NOTE: Mixing PSUs from previous generations of Dell PowerEdge servers can
result in a PSU mismatch condition or failure to turn the system on.
D Flashing amber Indicates a problem in the PSU.
14 About your system