Deployment Guide

52 Dell EMC XC Xpress Hyper-Converged Appliance Deployment Guide for Hyper-V | A02
7. After the First time Boot Script (FTBU) completes successfully wait five minutes before you launch the
Nutanix Foundation Applet. You can find the Nutanix First Time Boot Script procedure in section 4.1.
Note: The wait allows the CVM to complete boot up sequence on the appliance.
8. Run Fabric Manager on management workstation to identify any other potential network issues
affecting discovery process.
9. If you have followed all the steps above and still cannot see your appliances, then call Dell EMC
Customer Support.
C.3 Cluster creation does not complete successfully
If your clusters did not build successfully, you will see a screen like in Figure 25.
Cluster creation failed.
If your cluster creation does not complete successfully:
1. Retry imaging failed appliances with last configuration.
2. If the imaging retry fails, collect the log files and contact Dell Customer Support.
a. In the Cluster Creation Status table, under Log, click the link to the specific log file.