Deployment Guide
39 Dell EMC XC Xpress Hyper-Converged Appliance Deployment Guide for ESXi | A02
B.2 Desired appliances are not discovered in Foundation Launcher.
Appliances are not discovered using Foundation Launcher.
B.2.1 Ensure management workstation is connected on the same production
network.
1. Ensure all network cables are connected. For more information, see Installing hardware.
2. If using the 10 Gbe switch, ensure the correct Small Form factor Pluggable (SFP) is connected. For
supported cabling, see Dell EMC XC430 Xpress Series Support Matrix.
3. Ping default gateway or any other system from management workstation. For information about
making ping work see the section, “Resolving ping issues.”
4. Make sure the TCUP and UDP ports are open.
IMPORTANT: If you have connectivity issues discovering appliances in the Foundation applet verify the
following ports are opens. For the Foundation applet to work properly, you must open the following ports for
both IPv4 and IPv6 on the local system from which the applet is launched:
UDP on port 13000 (Nutanix discovery protocol)
TCP on ports 8000 (Foundation GUI)
TCP on 9442 (proxy)
TCP on 9443 (applet control)
5. Ensure all appliances are turned on and that both power supplies are plugged in properly and there is
no Yellow flashing light on any of the power supplies.
6. Ensure First Time boot has completed successfully on each appliance.
a. Go to C:\Program Files\Nutanix\Logs and open first_boot.log file.
b. Verify the last line “Marking first boot script run as a success” is there.