Administrator Guide

Table Of Contents
Device compliance status
By default, the following colors are displayed as the device status:
Red—when the registered device has not been checked in for more than seven days.
Gray—When you apply any conguration policy to the device.
Green—When you apply all the conguration policies to the device.
The default value can be changed from 1 to 99 days.
The Online Status option is located next to the device name. The following colors are displayed in the online status:
Red—When the device has not sent its heartbeat for more than three attempts .
Gray—When the device has not sent its heartbeat for more than two attempts but less than three attempts.
Green—When the device sends its heartbeat regularly.
Pulling Windows Embedded Standard or ThinLinux
image
Use the Wyse Management Suite to pull an operating system or BIOS from a thin client.
NOTE: You can upgrade ThinLinux from 1.x to 2.x.
Prerequistes:
If you are using Wyse Management Suite 1.3 remote repository, then Recovery/ Recovery + OS pull template are not available in the
repository. You must upgrade Wyse Management Suite to 1.4 to access the templates.
To perform ThinLinux image pull operation, you must close the Settings window in the ThinLinux device. You must perform this
operation before pulling an OS/OS+Recovery image from the ThinLinux device.
To upgrade from ThinLinux 1.x to 2.x, the administrator must update the device with the latest WDA and merlin and then pull the image.
This pulled image must be used to upgrade from ThinLinux 1.x to 2.x.
To perform the Windows Embedded Standard or ThinLinux image pull operation:
1 Go to the Windows Embedded Standard or ThinLinux device page.
2 Select Pull OS Image option, from the More Actions drop-down list.
3 Enter or select the following details:
Name of Image—Provide a name for the image. To replace the image with a similar name and the image les which are not
completed successfully, click Override name.
File repository—From the drop-down list, select the le repository to where the image is uploaded. There are two types of le
repositories:
Local repository
Remote Wyse Management Suite repository
Pull Type—Select either Default or Advanced based on your pull type requirement.
When the Default pull type is selected, the following options are displayed:
Compress
OS
BIOS
Recovery–—For ThinLinux 2.x
When the Advanced pull type is selected, a drop-down list for selecting the templates is displayed. Select any template which
is available by default.
NOTE
: You can use the custom templates created manually by editing the existing or default templates.
4 Click Prepare for Image Pull.
164
Managing devices