Administrator Guide
Option Description
• PS2: Port is configured for IBM PS2 compatibility.
• ECP: Port is configured for extended capability port protocol.
NOTE: This option is available for Wyse 5070 Extended
thin client when the add-on card is installed.
Serial Port 1 From the drop-down list, select the option to determine how the
serial port on the docking station operates. This option allows you
to avoid resource conflicts between devices by disabling or
remapping the address of the port.
• Disabled: Port is disabled.
• COM1: Port is configured at 3F8h with IRQ 4.
• COM2: Port is configured at 2F8h with IRQ 3.
• COM3: Port is configured at 3F8h with IRQ 4.
• COM4: Port is configured at 2F8h with IRQ 3.
Table 159. USB configuration
Option Description
Enable Front USB Ports Select this check box to enable the operating system to detect the
devices attached to the front USB port. However, if the USB port
is disabled, the operating system cannot detect the device
attached to the front USB ports.
NOTE: The USB keyboard and the mouse always work in
the BIOS setup irrespective of this setting.
Front port Top Select this option to enable the top USB port on the front of the
thin client.
Front port Top Medium Select this option to enable the top middle USB port on the front
of the thin client.
Front port Bottom Medium Select this option to enable the bottom middle USB port on the
front of the thin client.
Front port Bottom Select this option to enable the bottom USB port on the front of
the thin client.
Enable Rear USB Ports Select this check box to enable the operating system to detect the
devices attached to the back USB port. However, if the USB port
is disabled, the operating system cannot detect the device
attached to the back USB ports.
NOTE: The USB keyboard and the mouse always work in
the BIOS setup irrespective of this setting.
Rear port Top Left Select this option to enable the top left USB port on the back of
the thin client.
Rear port Top Right Select this option to enable the top right USB port on the back of
the thin client.
Rear port Bottom Left Select this option to enable the bottom left USB port on the back
of the thin client.
Rear port Bottom Right Select this option to enable the bottom right USB port on the back
of the thin client.
Table 160. Configuring security settings
Option Description
Enable Admin Setup Lockout Select this option to prevent others from entering the setup when
an administrator password is set.
Managing groups and configurations 81