Release Notes

Wyse Management Suite Version 1.1 | 11
Sl.no
Known issues
Workaround
disabling VNC User required
password option.
20.
Add Policy and Add Advance
Policy buttons becomes non-
function after app folders is
removed.
Do not delete the repository folder.
21.
Deleting inventory files manually
from the physical path
(c:\repository\data) does not
remove the files from Wyse
Management Suite UI (File does
not exist error pop-ups).
Do not delete the file from the repository folder
manually.
22.
ThinOS applications are getting
installed twice when the
applications are pushed along with
firmware (Apply to new device
option).
Root reason for downloading pkg twice is that root
disk gets formatted whenever base.pkg is upgraded
or downgraded.
23.
Import tool is allowing to import
RSP packages even if we delete
any
file(part1Image.img,vmlinuz,mbr
etc.) from RSP packages on WDM
repository and then if we do RSP
package import.
Valid RDP packages should be present in the WDM.
24.
Wyse Management Suite gets 404
error.
Verify whether any Antivirus deleted the java code.
25.
Windows Embedded Standard
application download fails.
Application download authentication is required for
all but the first release of WES agent.
If the application download fails with https, try with
http.
26.
During un-register or Remove
Policy, device gets reverted to the
Work group from domain if it is
added to the domain.
Administrator has to do the default policy for domain
settings, and it should be deployed.
27.
RemoteFX USB redirection policy
is not applied for USB mass
storage devices.
Add the following registry entries to the device:
1. Log in to the device as administrator and disable
the Write Filter.
2. Go to Run, and type regedit.
3.Go to HKLM\Software\Policies\Microsoft\Windows
NT\Terminal
Services\Client\UsbSelectDeviceByInterfaces
4.Add a string registry key 100 and set the value as
below:
For Mass Storage Device{53F56307-B6BF-11D0-
94F2-00A0C91EFB8B}.
For CD ROM{53F56308-B6BF-11D0-94F2-
00A0C91EFB8B}.
NOTE: Flower brackets are mandatory.
28.
USB lockdown configuration is not
applied while clicking update now
but it applies after log off and log
in again.
This issue is for Wyse software thin clients.
29.
Microsoft Gina configuration gets
failed while applying.
Select languages with substitute keyboard layouts.
30.
When you push SD command as
part of RSP, Windows Embedded
WDM devices get shutdown and sends V02 before
getting shutdown.
This is not supported for Wyse Management Suite.