Administrator Guide
Figure 47. Repository capable
Creating PAD Capable Images for Windows Devices
To create a PAD capable image for WES7, WE8S and WIE10devices:
1 Set the device check-in interval to at least one hour in the WDMVXC-M GUI Preferences.
2 Log in to the device as an Administrator, disable the Write Filter, log out , and log in again as Administrator.
3 Delete the HagentSettings.ini le from C:\Program Files\Wyse\WDA\congC:\Program Files\VXC-M and run the following
command in the command prompt for WES7 devices:
Hagent.exe -Install
For WE8S and WIE10 devices, you must log in as Administrator, navigate to C:\Windows\System32, right click the Cmd.exe le, and
select the Run as Administrator option before running the above command.
4 For WES7 devices, prepare the device to pull the image by navigating to the C:\windows\setup folder in the command prompt and
running the following command:
WES7_CustomSysprep4man.bat -r
For WE8S and WIE10 devices, prepare the device to pull the image by navigating to the C:\windows\setup folder in the command
prompt and running the following commands:
Powershell.eexe c:\windows\setup\WIE10_CustomSysprep4man.psl -r
NOTE
: For WE8S devices, you must run the command prompt as an Administrator. See Step 3.
5 Do not allow the device to boot to the OS, instead give the Pull Image command using the PXE mode for WES7 devices, and the
Non PXE mode for the WE8S and WIE10 devices where the sysprep is running.
6 Log in to the system where the WDMVXC-M console is running, and right click on a schedule from Update Manager > Schedule
Packages.
7 Select the Roll to Boot option.
8 For WES7 devices, press the P key, and boot the device through the PXE LAN mode. For WE8S and WIE10 devices, press the P key,
and boot the device through Merlin Non-PXE mode.
9 After the image is pulled, deploy the pulled image using the Deploy via Peers in Subnet option.
Conguring PAD
For the PAD feature to function, you need to congure the Subnet preferences. You can specify the number of devices that you want to
serve as repositories and also specify the connection details to the master device.
System
65