Administrator Guide

NOTE: Cert.pem is used to create certicate package and deploy to the ThreadX 4.x
clients.
Before upgrading the ThreadX devices, use the following guidelines:
To discover ThreadX devices using DNS SRV record: Adding the DNS SRV Record
To deploy the certicate to ThreadX 4.x devices :Deploy the certicate to ThreadX 4.x Devices
To upgrade the ThreadX devices: Upgrading the client rmware to ThreadX 5.x
Deploy the certicate to ThreadX 4.x Devices
To deploy the certicate to ThreadX 4.x devices, do the following:
1 Launch the WDM GUI and login to WDM with administrator privilege.
2 Go to Applications > PCoIP Conguration Packages.
3 Click the + button and download the PCoIP conguration manager utility.
4 Launch the utility which is downloaded and select Version 4.x radio button.
5 Click the Security option, and enable certicate checkbox.
6 Copy the cert.pem certicate contents including the rst and last line (Begin certicate and End certicate).
7 Paste the cert.pem contents in the text box provided.
8 Enter the name and the description for the package in the respective text box.
9 Click on Register menu and save the conguration.
10 Go to Devices page in WDM Web UI and select the desired device using the check box provided.
11 Click on the update button, select the created conguration package from PCoIP Conguration Packages category and click save.
12 Go to Jobs page and conrm that the package deployment is successfully completed.
Upgrading client rmware to ThreadX 5.x
Deploying Teradici image version 5.x
To update the zero clients running 4.8.0 rmware version that has been updated with the new WDM 5.7.2 certicate or, if the security
mode on the client is low, the Teradici rmware update Repository Support Package (RSP) must be created with the OLD OS type as TDC.
This is required for upgrading the rmware from compatible 4.x version to 5.x.
To create RSP package, do the following:
1 Go to the Teradici support site, and download the latest ThreadX 5.X rmware.
2 Create a le with the following contents, save the le in .rsp format and provide the le name as number value in the le.
NOTE
: The value of the
Number
eld is the name of the rmware le. In the following example, the value is
522r5_2@39075.03b193e.5957929.
[Version]
Number=522r5_2@39075.03b193e.5957929
Description=PCoIP Tera2 Firmware Release 5.2.2 for P25, P45, and 5050 AIO
OS=TDC
ImageSize=0
ImageType=merlin
Category=Images
[Script]
RB
3 Create a folder and place the .all le.
Management of Teradici device using WDM
101