Reference Guide
the title of the pane is shown as Next Session Exclusion List. The system will not restart the Wyse Software thin client, and the
changes are not committed until an administrator restarts the Wyse Software thin client device manually.
NOTE: Dell Write Filter does not support registry filtering.
Unified Write Filter disk overlay
Unified Write Filter can be configured to store the overlay either in RAM (RAM-based), or in a pre-allocated file on the system volume
(disk-based). In a disk-based overlay, UWF uses a pre-allocated file that is created on the system volume to increase the available space
for the overlay.
Due to the availability of more disk space in PCs, Wyse Converter for PCs 2.0 configures the UWF to store the overlay in a pre-allocated
file on the system volume (disk-based) and configures the size as per the following table:
Table 2. UWF disk overlay size
Disk size UWF Disk Overlay
Less or equal to 10 GB 2 GB
More than 10 GB 4 GB
More than 25 GB 8 GB
Dynamic RAMDisk configuration based on Write Filter status
RAMDiskSize application monitors and determines the RAMDisk size based on the status of Write Filter. When the write filter is enabled,
the RAMDiskSize is set to 100 MB. If the system RAM is less than 4 GB, and the write filter is disabled, the RAMDiskSize is set to 100 MB.
Also, the system temp is redirected to C:\Windows\Temp.
If the system RAM is 4 GB or higher, then the RAMDiskSize is set to 2 GB.
On Windows 7 32-bit operating system, if the RAM is set to more than 4 GB then the RAMDiskSize is also set to 4 GB. This is because
Windows 7 32-bit operating system supports only 4 GB SKU of RAM.
Wyse Easy Setup
Wyse Easy Setup enables administrators to quickly and easily deploy configurations on devices with Wyse Converter for PC. You can
create a kiosk mode to lock down the device to prevent users from accessing any features or functions on the device outside of the kiosk
mode. You can also customize the kiosk interface to enable or disable user access to specific settings. The customized desktop can be
configured on-premise or remotely using Wyse Management Suite.
Wyse Easy Setup can be installed as part of Wyse Converter for PCs 2.0 installation.
Wyse Easy Setup enables you to:
• Create a dedicated browser-focused client by configuring the Internet Explorer settings.
• Configure multiple broker connections such as Citrix, VMWare, and Remote Desktop Protocol (RDP).
• Configure a device to provide a dedicated application for a particular line of business.
• Create custom desktop with lockdown settings for end user.
• Configure a kiosk mode to lock down a Windows device to prevent users from accessing any features or functions on the device
outside of the kiosk mode. You can also customize the kiosk interface to enable or disable user access to specific settings.
Desktop lockdown UI during installation phase
The look and feel of the Wyse convertor for PCs installer UI is changed for customization workflow and better user experience.
Factory reset
You can reset the thin client to factory default settings using Microsoft Windows Recovery tools.
For more information, see White papers.
4