Release Notes
PCoIP Zero Client Firmware Version 5.5.1 | 4
Important notes
Wyse Device Manager
Wyse Device Manager v5.7.2 and v5.7.1 support 4.x, 5.2.2, 5.4.1, and 5.5.1 versions of
firmware.
Earlier versions of Wyse Device Manager support only 4.x. If you are using earlier versions of
Wyse Device Manager, then upgrade the Wyse Device Manager to version 5.7.1, and
proceed with the firmware update.
Teradici console
PCoIP Management Console v2.x cannot detect or manage devices on firmware versions
prior to v5.0. If you upgrade from firmware v4.x, then either the zero client AWI or PCoIP
Management Console v1.10.3 - v1.10.8 must be used to upgrade the zero client to firmware
v5.x.
Zero clients on firmware v5.x can only be managed by PCoIP Management Console v2.0 or
later. PCoIP Management Console v1.x cannot detect or manage devices on firmware v5.0 or
later.
Zero clients upgraded to firmware 5.x from a 4.x release must first be upgraded to firmware
v4.7 or v4.8.
The file contains .all extension for use by the Administrative Web Interface (AWI), and a file
identified by the .pcoip extension for use by PCoIP Management Console v2.x.
The .pcoip file contains zero client firmware v5.5.1 for Tera2 PCoIP Zero Clients only.
Support platforms
This release supports the following platforms:
Wyse 5030 zero client for VMware and AWS
Wyse 5050 AIO thin client for VMware and AWS
Wyse 7030 zero client for VMware and AWS
Upgrade scenarios
The following are the different upgrade scenarios for this product:
Upgrade path from 5.2.2 or 5.4.1 to 5.5.1 (ThreadX 5.x) using Wyse Device Manager.
Upgrade path from 4.8 (ThreadX 4.x) to 5.5.1 (ThreadX 5.x) using Wyse Device Manager.
Upgrade path using Teradici Console.
Customers who are using Teradici Console need to follow the Teradici instructions available
at Teradici Knowledge Base.