Issue number Description
WS-2193 Wyse Device Agent does not report IP address to the Wyse
Management Suite.
WS-2194 Wyse Management Suite does not report Custom elds from
Windows 10 IoT Enterprise devices.
WS-2195 C-A-D tool—Win+L Hotkey.
WS-2196 Incorrect passwords are displayed in the Registry-Auto login eld.
WS-2197 Blank space is added in the unquoted service path of Wyse Device
Agent (WDA).
Known issues
Table 12. Known issues
Issue number Description Workaround
WS-640
Low memory issue is observed when you set the Write
Filter threshold to 512 MB on thin clients, and the
application crosses the threshold limit on Wyse 7020 thin
client, Wyse 7020 accelerated graphics thin client, and
Wyse 5020 thin client.
For example, running 1080p video on multiple tabs
simultaneously (more than three tabs).
There is no workaround available.
WS-1362 When you use SCCM client to pull the image, the system
fails to boot. This is a known issue on Windows 10 IoT
operating system.
There is no workaround available.
WS-2141 The Windows To Go window does not open when you
click the icon in the Control panel with write lter
enabled.
Disable write lter.
WS-2080 Low memory issue is observed when you open multiple
applications.
Install Overlay Optimizer.
For installation steps, see Overlay Optimizer Release Notes
at downloads.dell.com/wyse/.
WS-2154 The error message Windows could not complete
the installation. To install Windows on
this computer, restart the installation
is displayed, while imaging from Wyse Management Suite
server with Logitech HD Webcam C930e and when
multiple USB drives are connected to the device.
During imaging, do not connect any external devices
except keyboard and mouse.
WS-1329 When you move an application to other location in the
start screen, the application gets disabled.
There is no workaround available.
WS-1525 Unknown IP as subnet is observed during PAD imaging. There is no workaround available.
Microsoft Windows 10 IoT Enterprise Threshold 1 for Wyse 5020 and 7020 Thin Clients Maintenance Release 4