Parameter
* Global overrides identically-named user profile
** After sign off, user profile returns to global value
Description
Device=Mobile
TrackpadDisable={yes, no}
[CloseLidCharge={No, ShutDown, OffDisplay}]
[CloseLidDisCharge={No, ShutDown, OffDisplay}]
[BatteryAutoPowerOff={3-20}]
Device =Mobile—This option is applicable only to the Wyse 5470
Thin Client.
TrackpadDisable={yes, no}—Default value is no. The Yes/No
option enables or disables the trackpad.
[CloseLidCharge={No, ShutDown, OffDisplay}]—This parameter is
applicable for the Wyse 5470 Thin Client. This option specifies the
thin client behavior when you close the lid of the thin client
connected to an external power source and not running on battery.
The following are the values that you can set for CloseLidCharge:
No—No action is taken when the lid is closed.
ShutDown—The thin client shuts down when the lid is closed.
OffDisplay—The built-in display and any external displays
connected to the thin client are turned off when the lid is
closed. This is the default value.
[CloseLidDisCharge={No, ShutDown, OffDisplay}]-This parameter
is applicable for the Wyse 5470 Thin Client. This parameter
specifies the thin client behavior when you close the lid of the thin
client running on battery and not connected to any external power
source.
The following are the values that you can set for
CloseLidDisCharge:
No—No action is taken when the lid is closed.
ShutDown—The thin client shuts down when the lid is closed.
This is the default value.
OffDisplay—The built-in display and any external displays
connected to the thin client are turned off when the lid is
closed.
[BatteryAutoPowerOff={3-20}—This parameter is applicable to
the Wyse 5470 Thin Client when it is on low battery.
This option specifies that the device shuts down if battery capacity
is lower than your set value. The value margin is 3–20 and the unit
is percentage.
LpdSpool={0-50}
Specifies the size of spool to buffer all the data before sending
them to the LPD printer. The range of value is 0–10, that is, 0 MB
to 10 MB. If the specified value is above the range, then the value is
set to 5.
The range of value is extended to 50.
In build 8.2_001 or later builds, the LPD data is spooled to a file in a
ram disk instead of a buffer. So the value of the parameter will not
be related to the spool size as before.
If LpdSpool=0, the function is disabled, otherwise the function is
enabled.
LPTPortBind={yes, no}
LPTPortBind — Default is Yes. Specifies the LPT bind to the
USB Port Policy.
If set to Yes, then the registered port follows the following binding
policy: LPT1 from USB ports 1/3/5/7 and LPT2 from USB posts
2/4/6.
If set to No, then the LPT port plugged in first is LPT1 followed by
LPT2, and so on.
66 Parameters for wnos INI, {username} INI, and $MAC INI files