Reference Guide
Parameter
* Global overrides identically-named user
profile
** After sign off, user profile returns to
global value
Description
If group pictures do not exist, global pictures are used. Supported formats include
JPG, GIF, PNG and BMP.
PictureTimer — Specifies the interval to wait in seconds to display another picture.
Default value is
6 seconds.
PictureOrder — Specifies the order of picture files to display. The default is to use
the order of sort from A to Z. If set to random, pictures are displayed randomly.
PictureCheck — Specifies whether to check for picture files servers or not.
NOTE:
If set to always, the picture files in file servers are checked when the
screen saver starts every time. By default, the system checks for picture
files only when the screen saver starts for the first time to decrease
network traffic.
PictureLayout— The optional parameter is used to specify the arrangement on the
desktop when pictures are displayed. For the tile selection, the image is replicated
across the desktop. For the center selection, the image is placed at the center of the
desktop without any image size change. For the stretch selection, the image is either
expanded or shrinked to fill the desktop. The default value is stretch.
Sleep—The optional parameter is used to specify the interval minutes to stop soft
screen saver and turn off monitor. After the specified minutes, since software screen
saver starts up, the software screen saver is stopped and turns off the monitor until
screen saver is off. The value range is 0–180. The value 0 is default which disables this
function.
**ShutdownCount={0 to 60} (seconds)
or
**ShutdownCounter={0 to 60} (seconds)
ShutdownCount or ShutdownCounter — Specifies the number of seconds to
count down before the shutdown sequence starts upon using the thin client power
button when there are active sessions.
The default value is 10, however, to commence shutdown immediately and prevent
the display of the countdown dialog box, set the value to 0.
ShutdownInfo={no, yes}
Yes/no option to display various information such as System Version, Terminal Name,
IP Address, and MAC Address in shutdown window.
SysinfoOntop=[yes,no]
This parameter enables the System Information window to be displayed at the top
in the Z-Order and overlaps on the nonmode switched full screen session window.
TimeServer=server_list
[TimeFormat={24-hour format, 12-hour
format}]
[DateFormat={yyyy/mm/dd, mm/dd/yyyy,
dd/mm/yyyy}]
[GetBiosDT={no, yes}]
TimeServer — Specifies the SNTP time servers to use for time retrieval. If a time
server is not defined, the client CMOS/ BIOS internal clock will be used as a
reference.
TimeFormat — Default is 24-hour format. Specifies the time format to use.
DateFormat — Default is yyyy/mm/dd. Specifies the date format to use.
NOTE:
The TimeFormat and DateFormat settings in a wnos.ini file will be saved
into NVRAM if EnableLocal=yes is set in the wnos.ini file.
GetBiosDT — Default is no. Yes/no option to obtain time from BIOS/CMOS when
the timeserver is not available or cannot be contacted.
For Example:
TimeServer=time.nist.com \
TimeFormat=24-hour format \
Parameters for wnos INI, {username} INI, and $MAC INI files 53