Release Notes
10. To disable local Winlock workstation provide /WD , for enabling local Winlock workstation, provide /WE.
11. And click Save and Yes to schedule a Job Immediately.
12. In App Policy Job, update Description
13. Run > Immediately and click Preview and click Schedule.
14. Go to Jobs for ensure the Job status.
15. Lock screen will be there when pushed from WMS.
Install the add-on using System Center Configuration
Manager 2016/2019—SCCM
Prerequisites:
1. Disable the write filter.
2. Add the thin client to the SCCM server domain and restart.
3. Log in to the thin client with valid SCCM domain credentials.
4. Change the time zone and time (HH:MM:SS) according to the SCCM server.
5. Go to Control Panel > Configuration Manager > Site > Configuration Settings.
6. In the Configuration Manager service location section, enter the site code.
7. In the Actions tab, select each action, and click Run Now.
A system tray message is displayed, and the new software is available for installation.
Add a device to the new device collection
This section describes the steps to add a thin client to the new device collection list.
1. Go to Assets and Compliance > Device Collections.
2. In the Devices list, right-click a device, and go to Add Selected Items > Add Selected Items to New Device collection.
3. In the Device Collections window, enter the new device collection details, such as name and limiting collection, and click OK.
4. In the Assets and Compliance section, click Device Collections, and verify whether the device is added.
Add a device to the existing device collection
This section describes the steps to add a thin client to the existing device collection list.
1. Go to Assets and Compliance > Device Collections.
2. In the Devices list, right-click a device, and go to Add Selected Items > Add Selected Items to Existing Device collection.
3. In the Device Collections window, select the device collection group to which you need to add the device, and click OK.
4. In the Assets and Compliance section, click Device Collections, and verify whether the device is added.
Create Application for CAD_MAP_VDI_WIE10_64bit.msi
1. Add the thin client to the Device Collection List.
2. Copy the file to local share.
3. Go to Software Library > Overview > Application management > Applications.
4. Right-click Applications and then select Create Applications.
5. Enter the local share location where the .msi file copied and select the .msi file and then click Next.
6. On the Import Information page, click Next.
7. Edit the installation program and add the parameter /q /forcerestart.
8. On the General Information page, select the Install behavior as Install for system and click Next.
9. Go to Software Library > Overview > Application management > Applications.
10. Right-click Applications and then select Distribute Applications.
11. Select the distribution point.
12. Refresh the application screen and ensure that the content status is Success before proceeding (It may take few minutes to complete
the distribution process).
13. Verify the details on the Summary page and then click Next.
CAD MAP VDI Enhancement (WIN+L support) version 3.0.3.0 and WinLock workstation version 3.0.3.0 Add-on
31