Release Notes
1. Log in as an administrator and disable UWF.
2. Copy the downloaded CAD_MAP_VDI_WIE10_64bit.msi file to C:\Temp folder.
3. Double-click the CAD_MAP_VDI_WIE10_64bit.msi file and follow the on-screen instructions.
4. Click Finish and enable UWF.
Installing Winlockworkstation.exe add-on manually in
client
The following are the steps to install Winlockworkstation.exe add-on manually in client:
1. Login to Admin account and Disable UWF.
2. Copy the Winlockworkstation.exe to C:\Temp folder (folder to be created).
3. Open command prompt with administrator privilege and go to the Winlockworkstation.exe location.
4. Run the command Winlockworkstation.exe /WD for disabling the local Winlock workstation and Winlockworkstation.exe /WE for
enabling the local Winlock workstation.
5. After the installation is complete, reboot the device.
6. Login to Admin account and Enable the UWF.
Installing CAD_MAP_VDI_WIE10_64bit.msi add -on using
Wyse Management Suite(WMS)
The following are the steps to install CAD_MAP_VDI_WIE10_64bit.msi add -on using Wyse Management Suite(WMS):
1. Register the Device to WMS server and add to respective add-on group.
2. Copy .msi file to the WMS server Repository.
3. Launch the browser and login to WMS Server with valid credentials.
4. Navigate to Portal Administration > File Repository.
5. Check the File Repository and select Sync Files
6. Go to Apps & Data > App Inventory > Thin Client ensure files listing in the Thin Client.
7. Go to Apps & Data > App Policies > Thin Client > Add Policy.
8. Fill all the mandatory fields (Policy Name, Group, Task, OS Type, Application, OS subtype Filter).
9. And click Save and Yes to schedule a Job Immediately.
10. In App Policy Job, update Description.
11. Run > Immediately and Click Preview and Click Schedule
12. Go to Jobs to ensure the Job status.
13. Lock screen is there when pushed from WMS.
Installing Winlockworkstation.exe add-on using Wyse
Management Suite (WMS)
The following are the steps to install Winlockworkstation.exe add-on using Wyse Management Suite (WMS):
1. Register the Device to WMS server and add to respective add-on group.
2. Copy .exe file to the WMS server Repository.
3. Launch the browser and login to WMS Server with valid credentials.
4. Go to Portal Administration > File Repository.
5. Check the File Repository and select Sync Files.
6. Go to Apps & Data > App Inventory > Thin Client, ensure files listing in the Thin Client.
7. Go to Apps & Data > App Policies > Thin Client > Add Policy.
8. Fill all the mandatory fields (Policy Name, Group, Task, OS Type, Application, OS subtype Filter).
9. Provide silent installation parameters.
30
CAD MAP VDI Enhancement (WIN+L support) version 3.0.3.0 and WinLock workstation version 3.0.3.0 Add-on