NOTE: RTME pkg 1.19 is for RTME 2.1.2.
Limitations of ICA Supercodec
ICA Supercodec is disabled automatically if the resolution is greater than 1920 x 1200, and under the Event log, System resolution exceeds
hardware limitation (1920 x 1200), disable Supercodec is printed.
INI parameters
The ThinOS v8.3.2 release contains the following newly added INI parameters:
Table 5. INI parameters
Parameter Description
PRIVILEGE=[None, Low, High]
[LockDown={yes, no}]
[HideSysInfo={yes, no}]
[HidePPP={yes, no}]
[HidePN={yes, no}]
[HideConnectionManager={yes, no}]
[EnableNetworkTest={yes, no}]
[EnableTrace={yes, no}]
[ShowDisplaySettings={yes, no, ddc-only}]
[EnableKeyboardMouseSettings={yes, no}]
[KeepDHCPRequestIP={yes, no}]
[SuppressTaskBar={yes, no, auto}]
[EnablePrinterSettings={yes, no}]
[CoreDump={ide, disabled]
[EnableNetworkSetup={yes, no}]
[DisableNetworkOptions={yes, no}]
[EnableSystemPreferences={yes, no,
TerminalNameOnly}]
[DisableTerminalName={yes, A37no}]
[DisableSerial={yes, no}]
[DisableRotate={yes, no}]
[DisableChangeDateTime={yes, no}]
[EnableVPNManager={yes, no}]
[TrapReboot={yes, no}]
PRIVILEGE parameter controls the operator access to Thin appliance resources as show
below:
Table 6. Parameters
Parameter Operator privileges
None The System Setup selection on the desktop menu is disabled and the
Setup submenu can not be displayed.
The Connect Manager, Dialup Manager and PPTP manager dialog boxes
are disabled.
The Reset to Factory default checkbox in the Shutdown dialog window is
not available
Low The Network and Wireless selections on the Setup submenu are
disabled (grayed out). The Connection Settings dialog box (opened from
Connect Manager) is readable but not writable.
The Reset to Factory default check box in the Shutdown dialog window is
disabled.
High(defaul
t)
No restrictions and all Thin Appliance resources are available.
NOTE:
• If PRIVILEGE= None or Low is used, the Network Setup dialog box is disabled. If
it is necessary to access this dialog box and the setting None or Low is not
saved into NVRAM, remove the network connector and reboot. This brings up
the Network Setup dialog box.
• Local user mode does not make use of .ini les.
If the option LockDown = Yes is specied, the system saves in the ash device of this
privilege level. If the LockDown = No is specied, the system clears the privilege level from
the ash device to the default unlocked state. If the device is LockDowned without a high
privilege level, the device disables the G key reset on power-up. If you set a Privilege with
High or Low or None, the four parameters HideSysInfo, HidePPP, HidePN, and
HideConnectionManager function as shown in the following table: