Reference Guide
If the settings are factory default or if you are upgrading to ThinOS
8.3 for the rst time, the value is temporarily set to low. After
loading any INI, it goes to Default value.
RapportServer=server_list
[Retry=]
IMPORTANT:
DISCONTINUED. DO NOT USE. Use WDMServer
parameter, see WDMServer=<server_list> in Table 4:
Connection Settings for wnos.ini Files Only.
Reboot | shutdown={no, yes} Time=hh:mm
[-hh:mm]
[Wday={Sunday, Monday, Tuesday, Wednesday, Thursday, Friday,
Saturday}]
[Idle=minutes]
Reboot — Yes/no option to enable automatic daily reboot of all
ThinOS devices.
Time — Species the time to reboot and must be in a 24-hour
format. For example: Reboot=Yes Time=17:30 will reboot all ThinOS
devices at 5:30 P.M. daily.
If you set time as hh:mm-hh:mm, a random time during the
congured time period is selected.
Wday— The option Wday species the week day of scheduled
reboot.
Idle— The option Idle species the idle minutes. After the
scheduled reboot time is reached, the unit reboots, if there is no
session or the terminal is idle for specied idle minutes. If the
session is still active, the reboot is delayed till the idle time is
reached or log o the sessions.
For example,
If you set Reboot=yes time=20:30, the unit reboots on local time
20:30. If you set Reboot=yes time=20:30-4:30, the unit reboots on
random time through 20:30 to 4:30.
If you set Reboot=yes time=23:00 Wday=Friday,Monday, the unit
reboots on local time 23:00 of Friday and Monday.
If you set Reboot=yes time=1:00 Idle=10, the unit reboots on 1:00, if
there are no sessions. If there is any active session, the reboot
happens only if the unit is idle for 10 minutes or the system logs out
from the session.
Since 8.3_012 or later, scheduling a shutdown at a given time is
supported. The options are same as schedule a reboot as above.
For example, Set Shutdown=yes time=20:30, the unit shuts down
at local time 20:30.
RegisterWINS=yes
Forces the thin client to register itself with a Microsoft WINS
server.
SelectServerList={PNA, VDI}
[Default=default_desc]
list of servers {Server1; Server2; ...ServerN}
Allows users to select one PNA or VDI server during logon. For
server use the format:
description = <server’s description> host = <server’s
url> [ <options>]
NOTE: There must be “description” and “host” key words
on each server.
For PNA server options, use the options of the PnliteServer
parameter in Table 7 Connection Settings: wnos.ini les, {username}
INI, and $MAC INI Files.
Parameters for WNOS INI les only 31