Administrator Guide

Table Of Contents
System log and trace information
Log/trace size and configuration
Table 53. Log/trace size and configuration
Type Cleanup after maximum
size
Comments
System log 10 MB No encryption. It is required that admin users do not open this
access to all other users. Only enable for target users.
Network/wireless trace 200 MB
USB packet 200 MB
HTTP log 10 MB
System configuration NA During export, ask admin to encrypt with password
How to enable and collect logs?
Table 54. Enabling and collecting logs
Type Enabling Capturing Collecting
System log Always enabled Always captured Using Wyse Management Suite or
USB drive
Network/wireless trace Enable in Admin
Policy Tool
Reboot after enabling Using Wyse Management Suite or
USB drive
USB packet Enable in Admin
Policy Tool
Reboot after enabling Using Wyse Management Suite or
USB drive
HTTP log Enable in Admin
Policy Tool
Reboot after enabling Using Wyse Management Suite or
USB drive
Upgrade or conversion troubleshooting and logs
Upgrade using Merlin imageindividual user
After a successful upgrade process, if there is no Wyse Management Suite, the system reboots to ThinOS 9.x OOBE screen.
Wyse Management Suite deployment
1. Refer Migration Guide or the Administrator's Guide of Wyse Management Suite 3.1 or later.
2. Upgrade Wyse Management Suite version to 3.1 or later versions.
At this stage the client is still running ThinOS 8.6.
3. Wyse Management Suite admin user configures two sets of policiesone for ThinOS 8.6 and the other for ThinOS 9.x.
For example, upload the ThinOS 9.1 conversion image to ThinOS 8.6 policy and upload ThinOS application packages to
ThinOS 9.x policy. At this stage the client is still running ThinOS 8.6
4. Push the conversion image from ThinOS 8.6 policy.
At this stage, the client updates from ThinOS 8.6 to 9.1 and starts reading the policy.
5. To finish the upgrade process, update ThinOS application package from ThinOS 9.x policy.
Troubleshooting your thin client
207