NOTE: Use NetBIOS or FQDN values to define an SSL (HTTPS) connection when enabling the TLSCheckCN option.
Enabling the TLSCheckCN option results in SSL connection failure when an IP address is defined.
4. Click Save & Publish.
Bloomberg keyboard support
ThinOS 9.1.2101 supports Bloomberg Keyboard STB 100. The keyboard has two connection methods. One method uses a single
USB cable to the USB port of the system. The second method is to connect dual USB cables to a KVM USB switch.
In a single USB cable connection, the keyboard device ID is vid-1188_pid-9545. All the six interfaces are under this device
ID.
In the dual USB cable connection, the keyboard device IDs are vid-1188_pid-9525 for one device and
vid-1188_pid-9535 for the other five devices.
Configure Bloomberg keyboard in Citrix sessions
Steps
1. On the ThinOS client, open Admin Policy Tool or go to the ThinOS 9.x policy settings on Wyse Management Suite.
2. On the Advanced tab, expand Peripheral Management, and click USB Redirection.
3. Click Add Row in the vUSB Force Redirect section:
Redirect the entire keyboard into the sessionThe keyboard feature keys, fingerprint reader, and the KVM Keyboard are
redirected into the session.
For Bloomberg keyboard that is connected with a single USB cable, add one row and enter the device ID. For
example, enter 0x11889545 to configure the device.
For Bloomberg keyboard that is connected with dual USB cables, add two rows and enter the device IDs. For
example, enter 0x11889525 in one row and 0x11889535 in the other.
Split keyboard and partly redirect into the sessionYou can redirect the keyboard feature keys, fingerprint reader, or the
KVM Keyboard individually.
For Bloomberg keyboard that is connected with a single USB cable, add one row and enter the device ID. For
example, enter 0x11889545010100. This configuration means that the interface 010100 is redirected into session
and other interfaces are not redirected.
For Bloomberg keyboard that is connected with dual USB cables, add one row and enter the device ID. For example,
enter 0x11889545030001. This configuration means that the interface 030001 is redirected into session and other
interfaces are not redirected.
4. Click Save & Publish.
Configure Bloomberg keyboard in PCoIP sessions
Steps
1. On the ThinOS client, open Admin Policy Tool or go to the ThinOS 9.x policy settings on Wyse Management Suite.
2. On the Advanced tab, expand Peripheral Management, and click USB Redirection.
3. Click Add Row in the vUSB Force Redirect section.
The Keyboard Feature keys, fingerprint reader, and the KVM Keyboard are redirected into the session.
For Bloomberg keyboard that is connected with a single USB cable, enter the device ID 0x11889545 to configure the
device.
For Bloomberg keyboard that is connected with dual USB cables, add two rows in the vUSB Force Redirect section,
enter 0x11889525 in one row and 0x11889535 in the other.
NOTE: PCoIP does not support USB device splitting.
4. Click Save & Publish.
Configuring connection brokers
115