For Bloomberg keyboard that is connected with a single USB cable, add one row and enter the device ID. For
example, enter 0x11889545010100. This configuration means that the interface 010100 is redirected into session
and other interfaces are not redirected.
For Bloomberg keyboard that is connected with dual USB cables, add one row and enter the device ID. For example,
enter 0x11889545030001. This configuration means that the interface 030001 is redirected into session and other
interfaces are not redirected.
4. Click Save & Publish.
Configure Bloomberg keyboard in PCoIP sessions
Steps
1. On the ThinOS client, open Admin Policy Tool or go to the ThinOS 9.x policy settings on Wyse Management Suite.
2. On the Advanced tab, expand Peripheral Management, and click USB Redirection.
3. Click Add Row in the vUSB Force Redirect section.
The Keyboard Feature keys, fingerprint reader, and the KVM Keyboard are redirected into the session.
For Bloomberg keyboard that is connected with a single USB cable, enter the device ID 0x11889545 to configure the
device.
For Bloomberg keyboard that is connected with dual USB cables, add two rows in the vUSB Force Redirect section,
enter 0x11889525 in one row and 0x11889535 in the other.
NOTE: PCoIP does not support USB device splitting.
4. Click Save & Publish.
Configure Bloomberg keyboard in VMware Blast sessions
Steps
1. On the ThinOS client, open Admin Policy Tool or go to the ThinOS 9.x policy settings on Wyse Management Suite.
2. In the Advanced tab, click Broker Settings, and expand VMware Broker Settings.
Redirect the entire keyboard into the sessionThe keyboard feature keys, fingerprint reader, and the KVM Keyboard are
redirected into the session.
For Bloomberg keyboard that is connected with a single USB cable, enter vid-1188_pid-9545 in the Include
Vid/Pid USB Device Redirection field.
For Bloomberg keyboard that is connected with dual USB cables, enter
vid-1188_pid-9525;vid-1188_pid-9535 in the Include Vid/Pid USB Device Redirection field.
Split keyboard and partly redirect into the sessionYou can redirect the keyboard feature keys, fingerprint reader, or the
KVM Keyboard individually.
For Bloomberg keyboard that is connected with a single USB cable:
a. Enter vid-1188_pid-9545 in the Include Vid/Pid USB Device Redirection field.
b. Enable the Allow Auto USB Device Splitting Redirection button.
c. Enter vid-1188_pid-9545(exintf:00;exintf:01;exintf:02) in the Split Vid/Pid Device field.
NOTE:
This configuration means that the interfaces 03, 04, and 05 are redirected into session and the other
interfaces 00, 01, and 02 are not redirected. 03, 04, and 05 are audio related interfaces. The analog headset
from the audio port in Bloomberg keyboard can be redirected into the Blast session.
For Bloomberg keyboard that is connected with dual USB cables:
a. Enter vid-1188_pid-9535 in the Include Vid/Pid USB Device Redirection field.
b. Enable the Allow Auto USB Device Splitting Redirection button.
c. Enter vid-1188_pid-9535(exintf:00;exintf:01) in the Split Vid/Pid Device field.
NOTE:
This configuration means that the interfaces 02, 03, and 04 are redirected into session and the other
interfaces 00 and 01 are not redirected. 02, 03, and 04 are audio related interfaces. The analog headset from
the audio port in Bloomberg keyboard can be redirected into the Blast session.
3. Click Save & Publish.
110