Reference Guide
17
Ensure that TEL placement is not defeated by simultaneous removal of multiple modules.
Allow 24 hours for the TEL adhesive seal to completely cure.
Record the position and serial number of each applied TEL in a security log.
Once applied, the TELs included with the AP cannot be surreptitiously broken, removed or reapplied
without an obvious change in appearance:
Each TEL has a unique serial number to prevent replacement with similar label. To protect the device from
tampering, TELs should be applied by the Crypto Officer as pictured below:
3.2.2 RAP-3WN/RAP-3WNP TEL Placement
This section displays all the TEL locations of the Aruba RAP-3WN. The RAP-3WN requires a minimum
of 2 TELs to be applied as follows:
3.2.2.1 To detect opening of the chassis cover:
1. Spanning the left and right chassis covers across the top of the chassis
3.2.2.2 To detect opening of the chassis cover and access to restricted ports
2. Spanning the left and right chassis covers and covering the proprietary console connector. Note
that the mount/stand should be attached first, and the TEL placed over the top of it.
Following is the TEL placement for the RAP-3WN and RAP-3WNP: