Aruba 7200 Series Controllers FIPS 140-2 Level 2 Security Policy
Figure 6 Required TELs for the Aruba 7200 Mobility Controller – Right Side
Figure 7 Required TELs for the Aruba 7200 Mobility Controller – Left Side
Figure 8 Required TELs for the Aruba 7200 Mobility Controller – Bottom
Applying TELs
The Crypto Officer should employ TELs as follows:
Before applying a TEL, make sure the target surfaces are clean and dry.
Do not cut, trim, punch, or otherwise alter the TEL.
Apply the wholly intact TEL firmly and completely to the target surfaces.
Press down firmly across the entire label surface, making several back-and-forth passes to ensure that the label
securely adheres to the chassis.
Ensure that TEL placement is not defeated by simultaneous removal of multiple modules.
Allow 24 hours for the TEL adhesive seal to completely cure.
Record the position and serial number of each applied TEL in a security log.
Once the TELs are applied, the Crypto Officer (CO) should perform initial setup and configuration as described in the next
chapter.