Reference Guide
30|
Aruba 7200 Series Controllers FIPS 140-2 Level 2 Security Policy
Required TEL Locations
The Aruba 7200 Mobility Controller requires a minimum of 15 TELs to be applied as follows:
To Detect Opening the Chassis Lid
Spanning the left side and right side of the chassis lid where it meets the chassis bottom, as shown in Figures 6,
7, and 8.
Spanning the front bezel and the chassis lid, as shown in Figures 3 and 4.
Spanning the expansion slot cover plate and the top of the chassis, as shown in Figures 3 and 4.
To Detect the Removal of Any Module or Cover Plate
Spanning power supply 1 and the top of the chassis, as shown in Figures 3 and 5. If a second power supply is
installed, a TEL should be applied to it in an identical way to power supply 1.
Spanning power supply 2 (if installed) and the top of the chassis, or spanning the power supply 2 cover plate and
the top and bottom of the chassis, as shown in Figures 3, 5, and 8.
Spanning the fan try and the top and bottom of the chassis, as shown in Figures 3, 5, and 8.
To Detect Access to Restricted Ports
Two labels spanning the RJ-45 and mini-USB serial ports, as shown in figures 4 and 8. Press down on this label
to ensure that it adheres to a sufficient area of the front bezel. The RJ-45 port is raised relative to the bezel so
there will be some air gap under the label in this area. However, the air gap should not be larger than 2-3mm.