Deployment Guide

12
Dell EMC Networking - Deploying VMware vSAN with OS10 Enterprise Edition | version 1.0
4.7 Node-facing configuration
Configure the vSAN node-facing interfaces with the following steps.
Switch-1 (S4148-ON)
Switch-2 (S4148-ON)
interface ethernet1/1/43
description "vSAN node 1 Port 1"
no shutdown
switchport mode trunk
switchport access vlan 1
switchport trunk allowed vlan 2030-
2032
mtu 9216
spanning-tree port type edge
interface ethernet1/1/45
description "vSAN node 2 Port 1”
no shutdown
switchport mode trunk
switchport access vlan 1
switchport trunk allowed vlan 2030-
2032
mtu 9216
spanning-tree port type edge
interface ethernet1/1/47
description "vSAN node 3 Port 1”
no shutdown
switchport mode trunk
switchport access vlan 1
switchport trunk allowed vlan 2030-
2032
mtu 9216
spanning-tree port type edge
interface ethernet1/1/49
description "vSAN node 4 Port 1”
no shutdown
switchport mode trunk
switchport access vlan 1
switchport trunk allowed vlan 2030-
2032
mtu 9216
spanning-tree port type edge
interface ethernet1/1/43
description "vSAN node 1 Port 2”
no shutdown
switchport mode trunk
switchport access vlan 1
switchport trunk allowed vlan 2030-
2032
mtu 9216
spanning-tree port type edge
interface ethernet1/1/45
description "vSAN node 2 Port 2”
no shutdown
switchport mode trunk
switchport access vlan 1
switchport trunk allowed vlan 2030-
2032
mtu 9216
spanning-tree port type edge
interface ethernet1/1/47
description "vSAN node 3 Port 2”
no shutdown
switchport mode trunk
switchport access vlan 1
switchport trunk allowed vlan 2030-
2032
mtu 9216
spanning-tree port type edge
interface ethernet1/1/49
description "vSAN node 4 Port 2”
no shutdown
switchport mode trunk
switchport access vlan 1
switchport trunk allowed vlan 2030-
2032
mtu 9216
spanning-tree port type edge