Deployment Guide

11
Dell EMC Networking - Deploying VMware vSAN with OS10 Enterprise Edition | version 1.0
1. Configure the VLTi port channel for dual-switch topologies on Switch-1 using the commands in the first
column of Table 2 (recommended port values shown).
2. Configure Switch-2 using the commands in column 2 provided in Table 2.
VLTi configuration
Switch-1 (S4148-ON)
Switch-2 (S4148-ON)
interface ethernet1/1/29-1/1/30
description VLTi
no shutdown
no switchport
vlt
-domain 127
backup destination 100.67.171.34
discovery-interface ethernet1/1/29-
1/1/30
interface ethernet1/1/29-1/1/30
description VLTi
no shutdown
no switchport
vlt
-domain 127
backup destination 100.67.171.35
discovery-interface ethernet1/1/29-
1/1/30
4.6 VLAN configuration
Configure the VLAN interfaces and Virtual Router Redundancy Protocol (VRRP). VRRP will be used as a
secondary form of redundancy.
Switch-1 (S4148-ON)
Switch-2 (S4148-ON)
interface vlan2030
description ESXimanagement
no shutdown
mtu 9216
ip address 172.20.30.251/24
vrrp-group 30
virtual-address 172.20.30.253
interface vlan2031
description vMotion
no shutdown
mtu 9216
ip address 172.20.31.251/24
vrrp-group 31
virtual-address 172.20.31.253
interface vlan2032
description vSAN
no shutdown
mtu 9216
ip address 172.20.32.251/24
vrrp-group 32
virtual-address 172.20.32.253
interface vlan2030
description ESXimanagement
no shutdown
mtu 9216
ip address 172.20.30.252/24
vrrp-group 30
virtual-address 172.20.30.253
interface vlan2031
description vMotion
no shutdown
mtu 9216
ip address 172.20.31.252/24
vrrp-group 31
virtual-address 172.20.31.253
interface vlan2032
description vSAN
no shutdown
mtu 9216
ip address 172.20.32.252/24
vrrp-group 32
virtual-address 172.20.32.253