- vLCM upgrade fails when Mellanox-nmlx4 Async 3.19.70.1 driver is installed
- Host seeding feature fails to perform when Dell EMC customized VMware 7.0 U2 A00 image is installed
- vLCM upgrade with Dell EMC 7.0 U1-A03 Custom Addon file with Intel-icen Async driver 1.4.2.0 fails
- VMware ESXi 7.0 U2 A00 fails to boot on upgrading from earlier ESXi version using custom offline bundles
- An ESXi host with Solarflare devices may experience PSOD during reboot post enabling SR-IOV
- Persistent memory datastore is not listed under vCenter
- iDRAC web interface displays incorrect status with ESXi inbox native driver
- Configuration changes made are not persistent across hosts that are restarted
- Operating system takes more time to complete boot when Intel DCPMM is configured in the interleaved app-direct mode
- All vCPUs assigned to a virtual machine are not visible in the guest operating system
- The Dell iSM and SFCB services fail to start after DCUI restarts the management agents
- Hostd core dump files are generated in /var/core on the VMware ESXi 7.0 host
- Virtual machine fails to start when Secure Encrypted Virtualization is enabled
- Virtual machine with Secure Encrypted Virtualization enabled uses only one VMware vCPU
- NVDIMM battery health status is displayed incorrectly on vCenter web client and ESXi host web client
- The health status of the SD cards are not updated under the Hardware Health tab
- Network connectivity is lost when virtual machines configured with Virtual Guest Tagging (VGT) are migrated to another ESXi host
- The Hardware Health tab of the vCenter Web Client does not display any information when a drive is removed
- Status of the NVMe devices configured as a host cache device is not updated after surprise removal
- Upgrading to ESXi 7.0 from earlier ESXi version fails
- VMware ESXi 7.0 does not boot after upgrading from VMware ESXi 6.5.x
- Upgrading to ESXi 7.0 from earlier ESXi version fails due to system management software incompatibility
- Installation of ESXi 7.0 fails on PowerEdge modular servers with BCM 5719 or 5720
- Surprise hot-plug of NVMe device is not supported
- Surprise hot-plug of an NVMe in a vSAN environment results in a PSOD
- The esxcli commands fail to locate the non-NVMe storage devices
- The option to start the NTP service does not work post configuration
- The driver modules qedf and qedi are not available for the QLogic 412xx adapter
- Unable to enable SRIOV on Solarfare devices with ESXi 7.0
- The rdma module for BCM 57416 devices fail to load in ESXi 7.0
- Uninstalling Dell EMC iSM VIB fails to delete files
- FCoE adapter speed is displayed as 0
- Status of the FCoE controller is displayed as offline
- The NIC description is incorrect
- The hardware label for PCIe devices is shown as Not appropriate
- Description of the NVMe drive displayed is incorrect
- Resources and support
- Contacting Dell EMC
The driver modules qedf and qedi are not available for
the QLogic 412xx adapter
Description:
In an ESXi 7.0 build, the driver modules qedf and qedi are not available for the QLogic 412xx adapter.
Applies to: ESXi 7.0
Workaround: Upgrade the in-box driver to the latest async drivers listed in the VMware HCL for ESXi 7.0 or use
VMware ESXi 7.0 A01 image or above. For more information, see VMware Knowledge Base article 78632.
Systems
affected:
All Dell EMC PowerEdge servers.
Tracking number: 149485
Unable to enable SRIOV on Solarfare devices with
ESXi 7.0
Description: With ESXi 7.0, the SROV feature cannot be enabled on the Solarfare devices. This issue is due to in-box
driver limitations. The in-box drivers do not have CIM providers required to enable SRIOV.
Applies to: ESXi 7.0
Workaround: Upgrade the in-box driver to the latest async drivers listed in the VMware HCL for ESXi 7.0 or use
VMware ESXi 7.0 A01 image or above.
Systems
affected:
All Dell EMC PowerEdge servers.
Tracking number: 148416
The rdma module for BCM 57416 devices fail to load in
ESXi 7.0
Description:
The rdma module for BCM 57416 devices fails to load in ESXi 7.0. This issue is due to the in-box driver
module bnxtnet limitations.
Applies to: ESXi 7.0
Workaround: Upgrade the in-box driver to the latest async drivers listed in the VMware HCL for ESXi 7.0 or use
VMware ESXi 7.0 A01 image or above.
Systems
affected:
All Dell EMC PowerEdge servers.
Tracking number: 148585
Uninstalling Dell EMC iSM VIB fails to delete files
Description:
Specific Dell EMC iSM directories are not deleted after uninstalling the Dell EMC iSM VIB.
Applies to: ESXi 7.0
Workaround: Reboot the host.
Systems
affected:
All Dell EMC PowerEdge servers.