Release Notes

Table Of Contents
vLCM upgrade with Dell EMC 7.0 U1-A03 Custom
Addon file with Intel-icen Async driver 1.4.2.0 fails
Description: Performing upgrade of host with Dell EMC 7.0 U1-A03 Addon that includes Intel-icen Async driver
v1.4.2.0, with vLCM single Image fails with the error message:
A general system error occurred. Component metadata or VIB relation error
Applies to: ESXi 7.0 U1
Workaround: Dell EMC 7.0 U1 A04 Custom image & above resolves this issue. It is recommended to use Dell EMC 7.0
U1 A04 custom image for upgrades and installation.
Systems
affected:
All Dell EMC PowerEdge servers that support ESXi 7.0 U1.
Tracking number: 195950
VMware ESXi 7.0 U2 A00 fails to boot on upgrading
from earlier ESXi version using custom offline bundles
Description: VMware ESXi 7.0 U2 A00 fails to boot on upgrading from earlier ESXi version using custom offline
bundles. The following error message is observed during boot:
Failed to load Crypto.efi Fatal Error:15
Applies to: ESXi 7.0
Workaround: None
Solution: For more information, see VMware Knowledge Base article 83063.
Systems
affected:
All Dell EMC PowerEdge servers
Tracking number: NIL
An ESXi host with Solarflare devices may experience
PSOD during reboot post enabling SR-IOV
Description:
An ESXi host with Solarflare devices may experience PSOD during reboot post enabling SR-IOV. This is a
known issue with ESXi 7.0 U1 and Solarflare devices.
Applies to: ESXi 7.0 x
Workaround: None
Solution: This issue is resolved in ESXi 7.0 U2.
Systems
affected:
Dell EMC PowerEdge 14G servers with Solarflare devices enabled for SR-IOV.
Tracking number: 185568
10 Known issues