Release Notes

ESXi DCUI displays lesser memory than the total
Description: For some Dell's 11th generation of PowerEdge systems with storage controllers PERC H200/H310 the ESXi DCUI
displays lesser memory than the total memory.
Applies to: ESXi 6.0
Solution: This is a known behavior.
ESXi installation may fail while deploying from virtual
media
Description: For some PowerEdge systems while installing VMware ESXi from virtual media with iDRAC virtual console
installation the installation stops responding if Spanning Tree Protocol is enabled and the iDRAC NIC is set as
Shared.
Applies to: ESXi 6.0 U2
Solution: Disable STP or do not connect iDRAC NIC to Shared.
Unable to boot ESXi 6.0 with Intel X710 devices
Description:
For Dell's 13th generation of PowerEdge systems with NPAR/NPAR EP enabled on Intel X710 NDC ESXi results in
Purple Screen of Death (PSOD) and does not boot.
Applies to: ESXi 6.0
Solution: Disable NPAR to boot ESXi successfully.
ESXi 6.0 host does not function and results in Purple
Screen of Death
Description:
For Dell's 13th generation of PowerEdge systems, when NPAR is enabled on Emulex network devices and VLAN is
congured, the ESXi host does not function and results in Purple Screen of Death (PSOD).
Applies to: ESXi 6.0
Solution: Disable NPAR or OS2BMC or VLAN conguration.
VMware ESXi host periodically disconnect and
reconnect from vCenter Server during heavy load on
storage subsystem
Description:
ESXi host gets disconnected periodically from vCenter Server during heavy load on storage subsystem. However,
the host gets reconnected automatically after some time.
Applies to: ESXi 6.0 U2
Solution: This issue can be ignored because there is no functionality loss.