Known issues
Topics:
Data integrity issue occurs when deleting virtual disks on ESXi system with PERC9 controller in RAID mode
qedf driver data integrity may fail at 256 KB block size
Uninstallation of Dell EMC OpenManage VIB fails to delete certain files
IPMI driver stack may stop responding when iDRAC hard reset is performed
Dell EMC PowerEdge Servers with VSAN All-Flash configuration and deduplication enabled, displays checksum error
After installing ESXi OS, ACPI error messages are displayed in the VMkernel log
PowerEdge 14th generations servers installed with ESXi are configured with default login credentials
By default, VMFS datastore is disabled on Dell EMC 14th generation PowerEdge Servers with factory-installed VMware
ESXi on BOSS-S1
Scratch partition stops working after hardware or software iSCSI is enabled on ESXi with the scsi-be2iscsi Emulex driver
In ESXi Hardware Status, vmnics displays Battery status
In ESXi host client, physical NICs reports duplicate entries of the speed supported
Embedded Host Client or vCenter Server reports an error when configuring SR-IOV
Virtual machines fail to power on, when System BIOS has MMIO set to 56 TB with Network Controllers enabled with NPAR
or NPAREP and SR-IOV
ESXi 6.0 U3 upgrade to ESXi 6.5 fails with UEFI Secureboot enabled
QLE2692 Network controller card is listed as QLogic Corp 2700
Operating system reinstallation on top of an existing ESXi installation on a BOSS device fails
NUMA related warning message is reported in VMkernel logs when Dell Fault Resilient Memory is enabled
iDRAC does not report the operating system information
Vendor label for certain hard drives report as NVMe
When iSM VIB is running on ESXi 6.0 U2, syslog file displays error messages intermittently
IPMI driver stack may stop responding when iDRAC hard reset is performed
Fault tolerance feature is not supported on AMD 63xx series processor
vSphere web client displays incorrect Service Tag for Dell EMC PowerEdge blade servers
Unable to upgrade VMware ESXi when the ESXi partition table contains a coredump partition
Configuring NVMe devices as passthrough device to the guest operating system, ESXi host stops responding and results in
PSOD
Power supply unit status and details are displayed incorrectly in vSphere Web Client or vCenter Server
Temperature status of the processor may display incorrectly in vSphere Web Client or vCenter Server
Storage-related sensor details are not available in vSphere Web Client or vCenter Server
Dell EMC PowerEdge Express Flash NVMe PCIe SSD device is not detected during hot-plug
VMs configured with Fault Tolerance might not be in a protected state
The status of LUN or disks is displayed as degraded
Dual port Mellanox card displays incorrect vmnic number
VMware ESXi installer lists local LUNs under the Remote section
Incorrect name for Dell PowerEdge FD332 storage controller
Software RAID is not supported for VMware ESXi
Status of some of the PCI devices is listed as Unknown on vCenter server
PSU wattage is not displayed for a ESXi host on the vCenter Server
ESXi Direct Console User Interface displays the hardware label as N/A
ESXi DCUI displays lesser memory than the total
ESXi installation may fail while deploying from virtual media
Unable to boot ESXi 6.0 with Intel X710 devices
ESXi 6.0 host does not function and results in Purple Screen of Death
VMware ESXi host periodically disconnect and reconnect from vCenter Server during heavy load on storage subsystem
Unable to write vmkernel coredump to local LUN when PSOD occurs
ESXi console displays an error message
2