Release Notes
Table Of Contents
- VMware vSphere 6 on Dell EMC PowerEdge Servers Release Notes
- Overview
- Known issues
- Data integrity issue occurs when deleting virtual disks on ESXi system with PERC9 controller in RAID mode
- qedf driver data integrity may fail at 256 KB block size
- Uninstallation of Dell EMC OpenManage VIB fails to delete certain files
- IPMI driver stack may stop responding when iDRAC hard reset is performed
- Dell EMC PowerEdge Servers with VSAN All-Flash configuration and deduplication enabled, displays checksum error
- After installing ESXi OS, ACPI error messages are displayed in the VMkernel log
- PowerEdge 14th generations servers installed with ESXi are configured with default login credentials
- By default, VMFS datastore is disabled on Dell EMC 14th generation PowerEdge Servers with factory-installed VMware ESXi on BOSS-S1
- Scratch partition stops working after hardware or software iSCSI is enabled on ESXi with the scsi-be2iscsi Emulex driver
- In ESXi Hardware Status, vmnics displays Battery status
- In ESXi host client, physical NICs reports duplicate entries of the speed supported
- Embedded Host Client or vCenter Server reports an error when configuring SR-IOV
- Virtual machines fail to power on, when System BIOS has MMIO set to 56 TB with Network Controllers enabled with NPAR or NPAREP and SR-IOV
- ESXi 6.0 U3 upgrade to ESXi 6.5 fails with UEFI Secureboot enabled
- QLE2692 Network controller card is listed as QLogic Corp 2700
- Operating system reinstallation on top of an existing ESXi installation on a BOSS device fails
- NUMA related warning message is reported in VMkernel logs when Dell Fault Resilient Memory is enabled
- iDRAC does not report the operating system information
- Vendor label for certain hard drives report as NVMe
- When iSM VIB is running on ESXi 6.0 U2, syslog file displays error messages intermittently
- IPMI driver stack may stop responding when iDRAC hard reset is performed
- Fault tolerance feature is not supported on AMD 63xx series processor
- vSphere web client displays incorrect Service Tag for Dell EMC PowerEdge blade servers
- Unable to upgrade VMware ESXi when the ESXi partition table contains a coredump partition
- Configuring NVMe devices as passthrough device to the guest operating system, ESXi host stops responding and results in PSOD
- Power supply unit status and details are displayed incorrectly in vSphere Web Client or vCenter Server
- Temperature status of the processor may display incorrectly in vSphere Web Client or vCenter Server
- Storage-related sensor details are not available in vSphere Web Client or vCenter Server
- Dell EMC PowerEdge Express Flash NVMe PCIe SSD device is not detected during hot-plug
- VMs configured with Fault Tolerance might not be in a protected state
- The status of LUN or disks is displayed as degraded
- Dual port Mellanox card displays incorrect vmnic number
- VMware ESXi installer lists local LUNs under the Remote section
- Incorrect name for Dell PowerEdge FD332 storage controller
- Software RAID is not supported for VMware ESXi
- Status of some of the PCI devices is listed as Unknown on vCenter server
- PSU wattage is not displayed for a ESXi host on the vCenter Server
- ESXi Direct Console User Interface displays the hardware label as N/A
- ESXi DCUI displays lesser memory than the total
- ESXi installation may fail while deploying from virtual media
- Unable to boot ESXi 6.0 with Intel X710 devices
- ESXi 6.0 host does not function and results in Purple Screen of Death
- VMware ESXi host periodically disconnect and reconnect from vCenter Server during heavy load on storage subsystem
- Unable to write vmkernel coredump to local LUN when PSOD occurs
- ESXi console displays an error message
- vmkernel log file displays an error message
- Unable to turn on Windows virtual machine when Dell PowerEdge Express Flash NVMe PCIe SSD is directly connected as a passthrough device
- Cannot enable SR-IOV on Intel X520 adapter using vSphere web client
- The PCI passthrough section on vSphere client or vCenter server does not display Dell PowerEdge Express Flash NVMe PCIe SSD
- Related information for virtualization solutions
- Getting help
ESXi 6.0 host does not function and results in Purple
Screen of Death
Description: For Dell's 13th generation of PowerEdge systems, when NPAR is enabled on Emulex network devices and
VLAN is configured, the ESXi host does not function and results in Purple Screen of Death (PSOD).
Applies to: ESXi 6.0
Solution: Disable NPAR or OS2BMC or VLAN configuration.
VMware ESXi host periodically disconnect and
reconnect from vCenter Server during heavy load on
storage subsystem
Description: ESXi host gets disconnected periodically from vCenter Server during heavy load on storage subsystem.
However, the host gets reconnected automatically after some time.
Applies to: ESXi 6.0 U2
Solution: This issue can be ignored because there is no functionality loss.
Unable to write vmkernel coredump to local LUN when
PSOD occurs
Description:
During heavy load on storage subsystem if PSOD occurs ESXi unable to write coredump to the local LUN
and results with the error message bad header error message.
Applies to: ESXi 6.0
Solution: Ensure that a network share is configured to coredump.
ESXi console displays an error message
Description:
ESXi console displays the error message CIM error: enumInstances Class not found in the ESXi technical
support mode or the ssh console.
Applies to: ESXi 6.0
Solution: This issue can be ignored because there is no functionality loss.
vmkernel log file displays an error message
Description:
During boot of VMware ESXi the vmkernel log file displays an error message ACPI Error: [CDW1]
Namespace lookup failure AE_NOT_FOUND.
Applies to: ESXi 6.0
Solution: This issue can be ignored because there is no functionality loss.