Release Notes

Table Of Contents
Dual port Mellanox card displays incorrect vmnic
number
Description: The dual port Mellanox card displays an incorrect vmnic number for the second port.
Applies to: ESXi 6.0 U2
Solution: There is no workaround.
VMware ESXi installer lists local LUNs under the
Remote section
Description: During VMware ESXi installation the local LUNs exposed from some PERC controllers are listed under the
Remote section of the installer.
Applies to: ESXi 6.0
Solution: This issue can be ignored because there is no functionality loss.
Incorrect name for Dell PowerEdge FD332 storage
controller
Description:
The storage controller for Dell PowerEdge FD332 is named as FS332 instead of FD332.
Applies to: ESXi 6.0 U2
Solution: This issue can be ignored because there is no functionality loss.
Software RAID is not supported for VMware ESXi
Description:
On-board SATA controller for Dell EMC PowerEdge servers provides an option to create RAID. The
software RAID LUNs are not supported because VMware ESXi does not carry supported drivers. Select
AHCI or ATA mode for SATA Controller on the BIOS Setup page and clear RAID mode.
Applies to: ESXi 6.0 U2
Solution: There is no workaround.
Status of some of the PCI devices is listed as
Unknown on vCenter server
Description:
On vCenter Server some of the entries status in the PCI device section of the Hardware Status tab on
the ESXi host are listed as Unknown.
Applies to: ESXi 6.0 U2
Solution: This issue can be ignored because there is no functionality loss.
Known issues 15