Release Notes

Systems
affected:
All Dell EMC PowerEdge servers
Tracking number: 100866
ESXi OS installed on IDSDM fails to boot when USB
3.0 is enabled
Description: On rebooting the Dell EMC PowerEdge R530, R430, and T430 servers, the ESXi OS installed on IDSDM
does not boot when the USB 3.0 controller is enabled on the server BIOS.
Applies to: ESXi 6.7.x
Workaround: Disable the vmkusb module on the affected servers by running the command:
#esxcli system module set m=vmkusb -e=FALSE
For more information, see VMware KB 2147650.
Systems
affected:
Dell EMC PowerEdge R530, R430, and T430 servers
Tracking number: 93275
While logging into OMSA, vSAN cluster experiences
Connection Error
Description:
While logging into OMSA, the vSAN cluster, under heavy utilization, experiences a Connection Error.
Applies to:
ESXi 6.7.x
openwsmand v2.2.1
Workaround: Restart the WSMan service by running the following command:
#/etc/init.d/wsman restart
Systems
affected:
All Dell EMC PowerEdge servers
Tracking number: 101360
Dell EMC customized VMware ESXi 6.7 A00 installer
fails to boot from PXE infrastructure
Description:
Dell EMC customized ESXi 6.7 A00 installer fails to boot from PXE infrastructure either in the UEFI or
BIOS boot modes and displays the following error message:
Error loading DellEMC_.v00 Fatal Error: 24 (TFTP error)
Applies to: ESXi 6.7.x
Workaround:
Go to TFTP/Web server and rename the ESXi 6.7 A00 file name from DellEMC_.v00 to
dellemc_.v00 or download and install the ESXi 6.7.x A01 image available at www.dell.com/support.
Systems
affected:
All Dell EMC PowerEdge servers
16 Known issues