Release Notes

3. To confirm that the value is set to 0, run the following command:
# esxcfg-advcfg -g /VSAN/ClomEnableInplaceExpansion
4. Repeat this process on all ESXi hosts in the vSAN cluster.
For more information, see the VMware KB article 58715.
Systems
affected:
All Dell EMC PowerEdge servers
Tracking number: NA
SR-IOV functionality is not available for QLogic 41xxx
adapter
Description: If the inbox native driver, qedentv-2.0.6.4-8, is installed on ESXi 6.7, Virtual Functions (VFs) cannot
be enabled on QLogic 41xxx adapter. Therefore, the SR-IOV functionality is not available.
Applies to: ESXi 6.7.x
Workaround: There is no workaround.
Systems
affected:
All Dell EMC PowerEdge servers
Tracking number: 99976
iDRAC web interface shows incorrect status with
ESXi inbox native driver
Description:
If the ESXi inbox native driver is installed, iDRAC web interface displays incorrect status for network card
details such as OS Driver State and Family Driver version.
Applies to: ESXi 6.7.x
Workaround: This issue can be ignored because there is no functionality loss.
For more information about the port link status, use vCenter Server or the esxcli command: esxcfg-nics -
l.
Systems
affected:
All Dell EMC PowerEdge servers
Tracking number: 86600
Dell EMC PowerEdge Express Flash NVMe PCIe SSD
device is not detected during hot-plug operation
Description:
When the Express Flash NVMe PCIe SSD namespace is set as Offline and the hot-plug operation is
performed in the same slot, the SSD is not initialized and detected.
Applies to: ESXi 6.7.x
Workaround: Perform one of the following steps:
If a different drive slot is available, reconnect the drive to the available drive slot.
Restart the sfcbd-watchdog service, and reinsert the drive.
Known issues 15