While logging into OMSA, vSAN cluster experiences
Connection Error
Description: While logging into OMSA, the vSAN cluster, under heavy utilization, experiences a Connection Error.
Applies to:
ESXi 6.7.x
openwsmand v2.2.1
Workaround: Restart the WSMan service by running the following command:
#/etc/init.d/wsman restart
Systems
affected:
All Dell EMC PowerEdge servers
Tracking number: 101360
Dell EMC customized VMware ESXi 6.7 A00 installer
fails to boot from PXE infrastructure
Description: Dell EMC customized ESXi 6.7 A00 installer fails to boot from PXE infrastructure either in the UEFI or
BIOS boot modes and displays the following error message:
Error loading DellEMC_.v00 Fatal Error: 24 (TFTP error)
Applies to: ESXi 6.7.x
Workaround:
Go to TFTP/Web server and rename the ESXi 6.7 A00 file name from DellEMC_.v00 to
dellemc_.v00 or download and install the ESXi 6.7.x A01 image available at https://www.dell.com/
support.
Systems
affected:
All Dell EMC PowerEdge servers
Tracking number: 100451
PCI devices status is listed as Unknown on vCenter
server
Description:
On vCenter Server installed on an ESXi host, the status of some of the devices under Hardware Status
> PCI device is displayed as Unknown.
Applies to: ESXi 6.7.x
Workaround: This issue can be ignored because there is no functionality loss.
Systems
affected:
All Dell EMC PowerEdge servers
Tracking number: 79601 and 87243