Figure 8. Target devices not displayed
Why does ESXi display the number of processors incorrectly
Cause:
This issue occurs if the Snoop mode option is set to Cluster on Die in the BIOS Memory Settings screen of a dual processor
system.
Resolution:
To display the accurate number of processors, ensure that the Snoop mode option is not set to Cluster on Die in the BIOS
Memory Settings screen.
26
Troubleshooting ESXi