Release Notes
Applies to: ESXi 5.0.x
Solution: This is a known issue.
Power management settings displayed as not supported
or not applicable
Description: On systems installed with AMD Opteron 6200 and AMD Opteron 4200 series of
processors, the Power Management settings in vCenter may be listed as not
supported or not applicable.
Applies to: ESXi 5.0.x
Solution: This is a known issue.
FC or iSCSI LUN details are not displayed in vCenter
server
Description: LUN details may not be listed in vCenter Server under Storage Adapters.
Applies to: ESXi 5.0.x
Solution: This is a known issue with the 1024 x 768 screen resolution. Increase the screen
resolution to resolve the problem.
IPMI related error messages logged in the vmkernel log
file
Description: IPMI related error messages, similar to the ones listed below, may get logged in
vmkernel.log file.
ipmi_si: Trying SMBIOS-specified kcs state machine at i/o
address 0xca8, slave address 0x20, irq 10
WARNING: VMK_VECTOR: 103: Bad vector 10 specified
WARNING: LinIRQ: request_irq:187:Couldn't register vector 0xa
ipmi_si: ipmi_si unable to claim interrupt 10, running polled
ipmi_si: Could not enable interrupts, failed set, using polled
mode
Applies to: ESXi 5.0.x
Solution: These messages can be safely ignored. This issue will be fixed in a future version of
ESXi release.
28