Release Notes
Upgrade from Dell customized VMware ESXi 5.0 ISO to a
later update fails
Description: When upgrading from Dell customized VMware ESXi 5.0 ISO to a later update, the
update fails with the following error message:
File path of/etc/vmware/oem.xml is claimed by Multiple overlay
VIBs
File path of/etc/vmware/support is claimed by Multiple overlay
VIBs:
File path of/etc/vmware/vmware.lic is claimed by Multiple
overlay VIBs:
Applies to: ESXi 5.0.x
Solution: This is a known issue. Follow any one of the options below to resolve the issue.
• Perform the upgrade by making use of a relevant upgrade patch from
vmware.com.
• Before you upgrade, run the following commands from ESXi tech support
mode.
~# esxcli software vib remove –n Dell-Configuration-VIB
~# esxcli software vib remove –n Dell-License-VIB
vmkernel Portgroups uses unused adapters when the
active adapter goes down
Description: If the Active NIC, which is part of a vmkernel portgroup fails, vSwitch starts using
the NIC under Unused Adapters. This happens when there are unused adapters
configured in the NIC teaming.
Applies to: ESXi 5.0.x
Solution: Set the Failback option available in NIC Teaming tab to Yes for that particular
vmkernel portgroup.
Scripted installation of Dell-Customized VMware ESXi
image fails
Description: When installing the Dell-Customized VMware ESXi 5.0 image using gPXE, the
scripted installation fails with a message: Dell-Con.v00: file not found:
Fatal Error: 15
Applies to: ESXi 5.0.x