Release Notes

ESXi host does not display the FAN RPM on Hardware
Status tab
Description: ESXi host does not display the FAN RPM under FAN section of Hardware Status
tab.
Applies to: ESXi 5.x
Solution: This issue can be ignored because there is no functionality loss.
Remote section of ESXi installer lists virtual disks created
with Dell PERC H200 controller
Description: During ESXi installation on systems with PERC H200 Controller, the virtual disks are
listed under the remote section of the installer.
Applies to: ESXi 5.x with PERC H200 Controller
Solution: This is a known issue and there is no functionality loss. For more information, refer
to the VMware Knowledge Base article 1027819.
Dell customized VMware ESXi 5.1 does not display FCoE
LUN during deployment
Description: The Dell customized version of the ESXi 5.1 installer does not display the FCoE LUN
during deployment.
Applies to: ESXi 5.1.x
Solution: This is a known issue. It will be fixed in future versions of Dell customized VMware
ESXi 5.1 images. Use the build for FCoE boot by VMware 5.1.x.
vCenter Hardware Health Status page displays Memory
Speed incorrectly
Description: VMware vCenter hardware health status displays incorrect memory speed when
compared to the system memory speed in BIOS.
Applies to: ESXi 5.x
Solution: ESXi reports only memory maximum speed field from SMBIOS, whereas the
property displayed in BIOS setup page is the configured memory clock speed. The
two properties are different. This is a known behavior and there is no functionality
loss.