Release Notes

1. Run the command, vmkchdev –p <Bus:Device.Function>, Where BDF is for
the NVMe device.
2. Edit the Edit /etc/vmware/esx.conf file, and enter /device/<<BDF of NVMe
device>>/owner = "passthru" in the file.
3. Restart ESXi. After the your restart ESXi, NVMe devices will be available for
VMs.
FCoE LUN gets disconnected from ESXi after system
restarts
Description: When Fibre Channel over Ethernet (FCoE) fabric is set up with multi-VLAN, the
FCoE LUN gets intermittently disconnected from ESXi after system restarts.
Applies to: ESXi 5.x
Solution: This is a known issue. Use only single VLAN for the FCoE FCF in VMware ESXi
environment.
Shared storage LUNs exposed from Dell PowerEdge VRTX
are not displayed under VMware ESXi
Description: After shared PERC8 firmware upgrade, LUNs exposed from Shared PERC8
controller are not displayed under VMware ESXi.
Applies to: ESXi 5.x
Solution: This is a known behavior. The LUNs are detected as snapshots after firmware
upgrade. For more information, refer to the VMware Knowledge Base article
1011387.
VMware ESXi installer displays an error message
“unrecognized disk label”
Description: During installation of VMware ESXi, the installer log (esxi_install.log) file
displays an exception error message unrecognized disk label for the local
disk.
Applies to: ESXi 5.5 U2 and later
Solution: This occurs when the local disk is not initialized as msdos/gpt. Initialize the local
disk as msdos/gpt before invoking the installer.