Release Notes
Release Notes 25
3
If you cannot upgrade the
ESXi image, downgrade
the iDRAC firmware to a
version earlier than 1.30.
During server boot, press
<F10> to get the USC
screen, or disconnect the
power cord and then
reconnect. Or, wait for 18
hours and start ESXi
installation. This disables
the USB device exposed by
USC.
VMware
vCenter Server
does not display
the correct
network
performance
details.
vCenter Server does not
display the correct
network performance
details because
vCenter Server is unable
to read data from the
ESX/ESXi host.
Use the esxtop command
on the ESX host to view the
correct network
performance details.
Use the resxtop command
available in VMware
vSphere CLI to get the
resource usage details of
ESX/ESXi remotely.
ESX/ESXi
4.0.x
When the storage
controller battery
is in the learning
mode, VMware
vSphere Server
displays the
following message:
I2C error
detected.
When the storage
controller battery is in
the learning mode, the
following message is
displayed in the
Hardware Status
tab of
VMware vSphere Server:
I2C error
detected.
There is no loss of
functionality. This error
message can be ignored.
ESX/ESXi
4.0
Update 1
Issue Description Resolution Applies to