Release Notes
24 Release Notes
The iDRAC
communication
stops when ESX
loads network
drivers.
The communication to
iDRAC stops when the
ESX NIC driver loads
under the following
conditions:
•The iDRAC NIC
interface is in shared
mode with the
on-board NIC.
• A VLAN ID is set for
the iDRAC network
interface.
However, iDRAC
responds until the
ESX/ESXi boot up
process begins the
Loading Network
Drivers phase.
The issue occurs because
the ESX NIC driver (bnx2)
cannot handle the VLAN
ID specified in the
iDRAC NIC.
NOTE: To resolve this issue,
do not use VLAN tagging for
iDRAC in shared mode;
instead, use the
asynchronous driver
available at the VMware
website. For more
information, see
kb.vmware.com/kb/1019513.
ESX/ESXi
4.0.x
ESXi 4.0
(Embedded
edition)
installation fails.
ESXi 4.0 installation
fails and the following
error message is
displayed:
Fatal Error: More
than one USB
device found.
Please remove USB
devices other
than the USB
key/SD card where
you wanted to
install ESXi.
The issue arises when
Unified Server
Configurator (USC) is
used for the operating
system deployment and
ESXi installation has
started on the server.
To resolve the issue:
1
If any additional USB
flash device is present on
the system, remove it.
2
Upgrade the ESXi image
to the Dell-customized
ESXi 4.0 Update 1 image
from
support.dell.com
, if:
• The iDRAC firmware is
later than or equal to
version 1.30.
• You can view the boot
device
LCDRIVE
when the system
boots up.
ESXi 4.0/
ESXi 4.0
Update 1
Embedded
edition
Issue Description Resolution Applies to