White Papers

Requirements
6 Dell EMC SC Series: Veeam Backup & Replication Integration | 4061-SC-SG
2 Requirements
This section describes the requirements to integrate Veeam Backup & Replication software with SC Series
storage.
Backup & Replication requirements:
Veeam Backup & Replication 9.5 Update 4b or newer is required.
Backup servers may be physical or virtual.
The SC Series plug-in is installed only on the backup server.
The SC Series plug-in is not installed on separate proxy servers.
iSCSI proxy servers may be virtual or physical.
Fibre Channel proxy servers must be physical and zoned to the SC Series storage.
The proxy server must have Fibre Channel or iSCSI fabric connectivity to the SC Series storage.
VMware vSphere Virtual Volumes (vVols) are not supported.
Physical mode Raw Device Mapping (pRDM) is not supported.
Veeam-specific features such as Explorer from Storage Snapshot, Backup from Storage Snapshot,
Snapshot only jobs, and On-Demand Sandbox for Storage Snapshots require an appropriate level of
Veeam licensing covered by Veeam Backup & Replication, Veeam Availability Suite, or Veeam
Essentials.
SC Series requirements:
Dell™ Storage Center OS (SCOS) 7.4 firmware is required.
An administrator-level account is required on SC Series storage to be used as Veeam credentials.
For security and audit best practices, this should be a service account.
Live Volumes are not supported.
There are no Dell EMC licensing requirements specific to Veeam integration.